You need JavaScript to view this

Tubular radiation source measurement for verification of the FP plate-out activities in the OGL-1 primary cooling system

Abstract

Activities and distribution of fission products (FPs), which plated-out in the primary cooling system of the High Temperature Engineering Test Reactor (HTTR), are important for the design, maintenance and accident analysis of the reactor. In the department of JMTR project, the distribution of FPs plated-out on inner surface of the primary cooling system piping of the high temperature gas cooling in-pile loop facility (OGL-1) has been measured during reactor operation and after shutdown. The OGL-1 is utilized for irradiation tests of the HTTR fuels. It became clear in the measurement that a large amount of {sup 137}Cs plated-out on the piping whose operation temperature was around 500degC, and {sup 137}Cs plated-out on the 500degC piping was released with decrease of FPs release from fuel to primary gas and redeposited on the piping in temperature range of 200-300degC. It was also found that {sup 131}I release rate from HTTR fuels in irradiation was 2x10{sup -7}-4x10{sup -5}. In this report, tubular radiation source measurement for verification of the FP plated-out activities in the OGL-1 primary cooling system was shown. Measurement error of plated-out activities in the OGL-1 primary cooling system was evaluated to be within 20%. (author).
Authors:
Matsumoto, Mikio; [1]  Ito, Haruhiko; Baba, Osamu; Itabashi, Yukio
  1. Nuclear Engineering Co., Hitachi, Ibaraki (Japan)
Publication Date:
Feb 01, 1994
Product Type:
Technical Report
Report Number:
JAERI-M-94-020
Reference Number:
SCA: 220600; 210300; PA: JPN-94:004134; EDB-94:080624; ERA-19:021583; NTS-95:001360; SN: 94001212224
Resource Relation:
Other Information: PBD: Feb 1994
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; IN PILE LOOPS; FISSION PRODUCTS; RADIATION DETECTORS; HELIUM; TEMPERATURE RANGE 0400-1000 K; PRIMARY COOLANT CIRCUITS; PIPES; DEPOSITION; SENSITIVITY; DATA COVARIANCES; HTTR REACTOR; JMTR REACTOR; CESIUM 137; IODINE 131; 220600; 210300; RESEARCH, TEST, TRAINING, PRODUCTION, IRRADIATION, MATERIALS TESTING REACTORS; POWER REACTORS, NONBREEDING, GRAPHITE MODERATED
OSTI ID:
10156064
Research Organizations:
Japan Atomic Energy Research Inst., Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Other: ON: DE94770636; TRN: JP9404134
Availability:
OSTI; NTIS; INIS
Submitting Site:
JPN
Size:
44 p.
Announcement Date:
Jul 06, 2005

Citation Formats

Matsumoto, Mikio, Ito, Haruhiko, Baba, Osamu, and Itabashi, Yukio. Tubular radiation source measurement for verification of the FP plate-out activities in the OGL-1 primary cooling system. Japan: N. p., 1994. Web.
Matsumoto, Mikio, Ito, Haruhiko, Baba, Osamu, & Itabashi, Yukio. Tubular radiation source measurement for verification of the FP plate-out activities in the OGL-1 primary cooling system. Japan.
Matsumoto, Mikio, Ito, Haruhiko, Baba, Osamu, and Itabashi, Yukio. 1994. "Tubular radiation source measurement for verification of the FP plate-out activities in the OGL-1 primary cooling system." Japan.
@misc{etde_10156064,
title = {Tubular radiation source measurement for verification of the FP plate-out activities in the OGL-1 primary cooling system}
author = {Matsumoto, Mikio, Ito, Haruhiko, Baba, Osamu, and Itabashi, Yukio}
abstractNote = {Activities and distribution of fission products (FPs), which plated-out in the primary cooling system of the High Temperature Engineering Test Reactor (HTTR), are important for the design, maintenance and accident analysis of the reactor. In the department of JMTR project, the distribution of FPs plated-out on inner surface of the primary cooling system piping of the high temperature gas cooling in-pile loop facility (OGL-1) has been measured during reactor operation and after shutdown. The OGL-1 is utilized for irradiation tests of the HTTR fuels. It became clear in the measurement that a large amount of {sup 137}Cs plated-out on the piping whose operation temperature was around 500degC, and {sup 137}Cs plated-out on the 500degC piping was released with decrease of FPs release from fuel to primary gas and redeposited on the piping in temperature range of 200-300degC. It was also found that {sup 131}I release rate from HTTR fuels in irradiation was 2x10{sup -7}-4x10{sup -5}. In this report, tubular radiation source measurement for verification of the FP plated-out activities in the OGL-1 primary cooling system was shown. Measurement error of plated-out activities in the OGL-1 primary cooling system was evaluated to be within 20%. (author).}
place = {Japan}
year = {1994}
month = {Feb}
}