Abstract
This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components`s parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test.
Citation Formats
Fuan, J.
Measurements of integrated components` parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests; Suivi de l`evolution des parametres de composants integres sous irradiation par rayonnement gamma (60Co) dosimetrie-methodologie-tests.
France: N. p.,
1991.
Web.
Fuan, J.
Measurements of integrated components` parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests; Suivi de l`evolution des parametres de composants integres sous irradiation par rayonnement gamma (60Co) dosimetrie-methodologie-tests.
France.
Fuan, J.
1991.
"Measurements of integrated components` parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests; Suivi de l`evolution des parametres de composants integres sous irradiation par rayonnement gamma (60Co) dosimetrie-methodologie-tests."
France.
@misc{etde_10154037,
title = {Measurements of integrated components` parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests; Suivi de l`evolution des parametres de composants integres sous irradiation par rayonnement gamma (60Co) dosimetrie-methodologie-tests}
author = {Fuan, J}
abstractNote = {This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components`s parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test.}
place = {France}
year = {1991}
month = {Dec}
}
title = {Measurements of integrated components` parameters versus irradiation doses gamma radiation (60Co) dosimetry-methodology-tests; Suivi de l`evolution des parametres de composants integres sous irradiation par rayonnement gamma (60Co) dosimetrie-methodologie-tests}
author = {Fuan, J}
abstractNote = {This paper describes the methodology used for the irradiation of the integrated components and the measurements of their parameters, using Quality Insurance of dosimetry: - Measurement of the integrated dose using the competences of the Laboratoire Central des Industries Electriques (LCIE): - Measurement of irradiation dose versus source/component distance, using a calibrated equipment. - Use of ALANINE dosimeters, placed on the support of the irradiated components. - Assembly and polarization of components during the irradiations. Selection of the irradiator. - Measurement of the irradiated components`s parameters, using the competences of the societies: - GenRad: GR130 tests equipement placed in the DEIN/SIR-CEN SACLAY. - Laboratoire Central des Industries Electriques (LCIE): GR125 tests equipment and this associated programmes test.}
place = {France}
year = {1991}
month = {Dec}
}