You need JavaScript to view this

Specification of a commercial SFAT device prototype. Interim report on Task A563 of the Finnish Support Programme to IAEA Safequards

Abstract

The project for the development of the Spent Fuel Attribute Tester (SFAT) under the Task-A-563 of the Finnish Support Programme has proceeded to the prototype design phase. Radiation data of the AFR Storage (TVO KPA-Store) of the TVO Power Company, Finland, relevant to the optimal design of the measurement geometry has been measured and will be shortly reported. The requirements and constraints imposed to this kind of device by the user (IAEA), nuclear safety authorities (represented by STUK) and the nuclear power companies (represented by TVO) have been worked out. The feasibility of a design that can be approved by all parties has been established. The specifications relevant for the design for the design of a commercial SFAT prototype, will be given. Considerations as for the operation procedure, maintenance and safety will be made. Finally, some recommendations for the further advancement of the SFAT prototype project will be given. (orig.). (1 ref., 5 figs., 2 tabs.).
Authors:
Tiitta, A; Pitkaenen, V; [1]  Tarvainen, M [2] 
  1. Technical Research Centre of Finland, Espoo (Finland)
  2. Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)
Publication Date:
Feb 01, 1992
Product Type:
Technical Report
Report Number:
STUK-YTO-TR-38
Reference Number:
SCA: 055001; 050900; 210100; PA: AIX-25:037534; EDB-94:079795; ERA-19:018274; NTS-94:022138; SN: 94001208188
Resource Relation:
Other Information: PBD: Feb 1992
Subject:
98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION; 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; SPENT FUEL ELEMENTS; IAEA SAFEGUARDS; BWR TYPE REACTORS; CESIUM 137; COBALT 60; FEASIBILITY STUDIES; FINLAND; GAMMA SPECTROSCOPY; MULTI-CHANNEL ANALYZERS; NAI DETECTORS; RADIATION DETECTION; SPENT FUEL STORAGE; UNDERWATER OPERATIONS; VERIFICATION; 055001; 050900; 210100; TECHNICAL ASPECTS; TRANSPORT, HANDLING, AND STORAGE; POWER REACTORS, NONBREEDING, LIGHT-WATER MODERATED, BOILING WATER COOLED
OSTI ID:
10152944
Research Organizations:
Finnish Centre for Radiation and Nuclear Safety (STUK), Helsinki (Finland)
Country of Origin:
Finland
Language:
English
Other Identifying Numbers:
Other: ON: DE94624801; ISBN 951-47-5959-1; TRN: FI9400022037534
Availability:
OSTI; NTIS; INIS
Submitting Site:
FIN
Size:
25 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Tiitta, A, Pitkaenen, V, and Tarvainen, M. Specification of a commercial SFAT device prototype. Interim report on Task A563 of the Finnish Support Programme to IAEA Safequards. Finland: N. p., 1992. Web.
Tiitta, A, Pitkaenen, V, & Tarvainen, M. Specification of a commercial SFAT device prototype. Interim report on Task A563 of the Finnish Support Programme to IAEA Safequards. Finland.
Tiitta, A, Pitkaenen, V, and Tarvainen, M. 1992. "Specification of a commercial SFAT device prototype. Interim report on Task A563 of the Finnish Support Programme to IAEA Safequards." Finland.
@misc{etde_10152944,
title = {Specification of a commercial SFAT device prototype. Interim report on Task A563 of the Finnish Support Programme to IAEA Safequards}
author = {Tiitta, A, Pitkaenen, V, and Tarvainen, M}
abstractNote = {The project for the development of the Spent Fuel Attribute Tester (SFAT) under the Task-A-563 of the Finnish Support Programme has proceeded to the prototype design phase. Radiation data of the AFR Storage (TVO KPA-Store) of the TVO Power Company, Finland, relevant to the optimal design of the measurement geometry has been measured and will be shortly reported. The requirements and constraints imposed to this kind of device by the user (IAEA), nuclear safety authorities (represented by STUK) and the nuclear power companies (represented by TVO) have been worked out. The feasibility of a design that can be approved by all parties has been established. The specifications relevant for the design for the design of a commercial SFAT prototype, will be given. Considerations as for the operation procedure, maintenance and safety will be made. Finally, some recommendations for the further advancement of the SFAT prototype project will be given. (orig.). (1 ref., 5 figs., 2 tabs.).}
place = {Finland}
year = {1992}
month = {Feb}
}