You need JavaScript to view this

Improvements of HCN laser heterodyne interferometer for measuring plasma density

Abstract

The improvements of a measuring method and laser performance in the HCN laser heterodyne interferometer system for plasma density measuring are introduced. A Fabry-Perot type output coupler which has optimal reflectance and transmittance is used to obtain maximum output power. The laser output power and frequency are stabilized by a micro-computer aided feedback control system. The fluctuation of output power is less than +-1% and the fluctuation of frequency is less than +- 77 kHz. There is no any frequency drift or power drift during long term operation. A new method for measuring phase shift in heterodyne interferometer is suggested. The phase shift is directly obtained from the probe beam, which reflects the variation of plasma density, without comparing with reference beat. The low limit of measurable phase shift is depending on the frequency of clock and the upper limit is infinite.
Authors:
Dingguo, Bi [1] 
  1. Southwest Inst. of Physics, Leshan, SC (China)
Publication Date:
Oct 01, 1992
Product Type:
Technical Report
Report Number:
CNIC-00679; SIP-0054.
Reference Number:
SCA: 700320; PA: AIX-25:038245; EDB-94:085821; ERA-19:020304; NTS-94:022123; SN: 94001208724
Resource Relation:
Other Information: PBD: Oct 1992
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; PLASMA DENSITY; FABRY-PEROT INTERFEROMETER; COMPUTERIZED CONTROL SYSTEMS; CYANIDES; FEEDBACK; FLUCTUATIONS; GAS LASERS; MODIFICATIONS; PHASE SHIFT; POWER CONDITIONING CIRCUITS; VARIATIONS; 700320; PLASMA DIAGNOSTIC TECHNIQUES AND INSTRUMENTATION
OSTI ID:
10152868
Research Organizations:
China Nuclear Information Centre, Beijing, BJ (China)
Country of Origin:
China
Language:
Chinese
Other Identifying Numbers:
Other: ON: DE94625037; ISBN 7-5022-0782-1; TRN: CN9400340038245
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
12 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Dingguo, Bi. Improvements of HCN laser heterodyne interferometer for measuring plasma density. China: N. p., 1992. Web.
Dingguo, Bi. Improvements of HCN laser heterodyne interferometer for measuring plasma density. China.
Dingguo, Bi. 1992. "Improvements of HCN laser heterodyne interferometer for measuring plasma density." China.
@misc{etde_10152868,
title = {Improvements of HCN laser heterodyne interferometer for measuring plasma density}
author = {Dingguo, Bi}
abstractNote = {The improvements of a measuring method and laser performance in the HCN laser heterodyne interferometer system for plasma density measuring are introduced. A Fabry-Perot type output coupler which has optimal reflectance and transmittance is used to obtain maximum output power. The laser output power and frequency are stabilized by a micro-computer aided feedback control system. The fluctuation of output power is less than +-1% and the fluctuation of frequency is less than +- 77 kHz. There is no any frequency drift or power drift during long term operation. A new method for measuring phase shift in heterodyne interferometer is suggested. The phase shift is directly obtained from the probe beam, which reflects the variation of plasma density, without comparing with reference beat. The low limit of measurable phase shift is depending on the frequency of clock and the upper limit is infinite.}
place = {China}
year = {1992}
month = {Oct}
}