Abstract

The present work represents a further study of the basic RTOF Fourier multipurpose diffractometer, to start with, at the ET-RR-1 reactor. The functions of the suggested arrangement are thoroughly discussed and the possibilities if its expansion are also assessed. The flexibility of the arrangement allows its further expansion both for stress measurement at 90 deg. scattering angle with two detector banks at opposite sides of the incident beam and for operation in the transmission diffraction mode. (orig.). (19 refs., 10 figs., 1 tab.).
Authors:
Maayouf, R M.A.; [1]  Tiitta, A T [2] 
  1. Atomic Energy Authority, Cairo (Egypt)
  2. Technical Research Centre of Finland, Espoo (Finland). Reactor Lab.
Publication Date:
Sep 01, 1993
Product Type:
Technical Report
Report Number:
VTT-TIED-1502
Reference Number:
SCA: 440103; PA: AIX-25:037304; EDB-94:083142; ERA-19:019480; NTS-94:022101; SN: 94001208028
Resource Relation:
Other Information: PBD: Sep 1993
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; NEUTRON DIFFRACTOMETERS; CRYSTALLOGRAPHY; DIAGNOSTIC USES; ETRR-1 REACTOR; FOURIER ANALYSIS; NEUTRON CHOPPERS; SLOW NEUTRONS; TIME-OF-FLIGHT SPECTROMETERS; 440103; NUCLEAR SPECTROSCOPIC INSTRUMENTATION
OSTI ID:
10152775
Research Organizations:
Technical Research Centre of Finland, Espoo (Finland)
Country of Origin:
Finland
Language:
English
Other Identifying Numbers:
Other: ON: DE94624721; ISBN 951-38-4436-6; TRN: FI9400037037304
Availability:
OSTI; NTIS; INIS
Submitting Site:
FIN
Size:
19 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Maayouf, R M.A., and Tiitta, A T. Multipurpose RTOF Fourier diffractometer at the ET-RR-1 reactor. Finland: N. p., 1993. Web.
Maayouf, R M.A., & Tiitta, A T. Multipurpose RTOF Fourier diffractometer at the ET-RR-1 reactor. Finland.
Maayouf, R M.A., and Tiitta, A T. 1993. "Multipurpose RTOF Fourier diffractometer at the ET-RR-1 reactor." Finland.
@misc{etde_10152775,
title = {Multipurpose RTOF Fourier diffractometer at the ET-RR-1 reactor}
author = {Maayouf, R M.A., and Tiitta, A T}
abstractNote = {The present work represents a further study of the basic RTOF Fourier multipurpose diffractometer, to start with, at the ET-RR-1 reactor. The functions of the suggested arrangement are thoroughly discussed and the possibilities if its expansion are also assessed. The flexibility of the arrangement allows its further expansion both for stress measurement at 90 deg. scattering angle with two detector banks at opposite sides of the incident beam and for operation in the transmission diffraction mode. (orig.). (19 refs., 10 figs., 1 tab.).}
place = {Finland}
year = {1993}
month = {Sep}
}