You need JavaScript to view this

Direct fourier methods in 3D-reconstruction from cone-beam data

Abstract

The problem of 3D-reconstruction is encountered in both medical and industrial applications of X-ray tomography. A method able to utilize a complete set of projections complying with Tuys condition was proposed by Grangeat. His method is mathematically exact and consists of two distinct phases. In phase 1 cone-beam projection data are used to produce the derivative of the radon transform. In phase 2, after interpolation, the radon transform data are used to reconstruct the three-dimensional object function. To a large extent our method is an extension of the Grangeat method. Our aim is to reduce the computational complexity, i.e. to produce a faster method. The most taxing procedure during phase 1 is computation of line-integrals in the detector plane. By applying the direct Fourier method in reverse for this computation, we reduce the complexity of phase 1 from O(N{sup 4}) to O(N{sup 3}logN). Phase 2 can be performed either as a straight 3D-reconstruction or as a sequence of two 2D-reconstructions in vertical and horizontal planes, respectively. Direct Fourier methods can be applied for the 2D- and for the 3D-reconstruction, which reduces the complexity of phase 2 from O(N{sup 4}) to O(N{sup 3}logN) as well. In both cases, linogram techniques are  More>>
Authors:
Publication Date:
Jun 01, 1994
Product Type:
Thesis/Dissertation
Report Number:
LIU-TEK-LIC-1993-55
Reference Number:
SCA: 550602; PA: AIX-25:036538; EDB-94:084148; ERA-19:019780; NTS-94:022089; SN: 94001207438
Resource Relation:
Other Information: TH: Thesis (TeknL).; PBD: Jun 1994; Related Information: Linkoeping Studies in Science and Technology, 413; Thesis
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; TOMOGRAPHY; IMAGE PROCESSING; DATA ACQUISITION; DATA PROCESSING; FOURIER TRANSFORMATION; GEOMETRY; THREE-DIMENSIONAL CALCULATIONS; 550602; EXTERNAL RADIATION IN DIAGNOSTICS
OSTI ID:
10152721
Research Organizations:
Linkoeping Univ. (Sweden). Dept. of Electrical Engineering
Country of Origin:
Sweden
Language:
English
Other Identifying Numbers:
Journal ID: ISSN 0280-7971; Other: ON: DE94624425; ISBN 91-7871-210-6; TRN: SE9400072036538
Availability:
OSTI; NTIS; INIS
Submitting Site:
SWDN
Size:
175 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Axelsson, C. Direct fourier methods in 3D-reconstruction from cone-beam data. Sweden: N. p., 1994. Web.
Axelsson, C. Direct fourier methods in 3D-reconstruction from cone-beam data. Sweden.
Axelsson, C. 1994. "Direct fourier methods in 3D-reconstruction from cone-beam data." Sweden.
@misc{etde_10152721,
title = {Direct fourier methods in 3D-reconstruction from cone-beam data}
author = {Axelsson, C}
abstractNote = {The problem of 3D-reconstruction is encountered in both medical and industrial applications of X-ray tomography. A method able to utilize a complete set of projections complying with Tuys condition was proposed by Grangeat. His method is mathematically exact and consists of two distinct phases. In phase 1 cone-beam projection data are used to produce the derivative of the radon transform. In phase 2, after interpolation, the radon transform data are used to reconstruct the three-dimensional object function. To a large extent our method is an extension of the Grangeat method. Our aim is to reduce the computational complexity, i.e. to produce a faster method. The most taxing procedure during phase 1 is computation of line-integrals in the detector plane. By applying the direct Fourier method in reverse for this computation, we reduce the complexity of phase 1 from O(N{sup 4}) to O(N{sup 3}logN). Phase 2 can be performed either as a straight 3D-reconstruction or as a sequence of two 2D-reconstructions in vertical and horizontal planes, respectively. Direct Fourier methods can be applied for the 2D- and for the 3D-reconstruction, which reduces the complexity of phase 2 from O(N{sup 4}) to O(N{sup 3}logN) as well. In both cases, linogram techniques are applied. For 3D-reconstruction the inversion formula contains the second derivative filter instead of the well-known ramp-filter employed in the 2D-case. The derivative filter is more well-behaved than the 2D ramp-filter. This implies that less zeropadding is necessary which brings about a further reduction of the computational efforts. The method has been verified by experiments on simulated data. The image quality is satisfactory and independent of cone-beam angles. For a 512{sup 3} volume we estimate that our method is ten times faster than Grangeats method.}
place = {Sweden}
year = {1994}
month = {Jun}
}