Abstract
An second international comparison on measuring techniques of tritium production rates for fusion neutronics experiments (ICMT-2) has been performed. The purpose is to evaluate the measurement accuracy of tritium production rates in the current measurement techniques. Two 14 MeV neutron source facilities, FNS at JAERI-Japan and LOTUS at EPFL-Switzerland, were used for this purpose. Nine groups out of seven countries participated in this program. A fusion simulated blanket assembly of simple-geometry was served as the test bed at each facility, in which Li-containing samples from the participants were irradiated in an uniform neutron field. The tritium production rates were determined by the participants using their own ways by using the liquid scintillation counting method. Tritiated water sample with unknown but the same concentration was also distributed and its concentration was measured to make a common reference. The standard deviation of measured tritium production rates among participants was about 10 % for both FNS and LOTUS irradiation levels: 4x10{sup -13} T-atoms/Li-atom and 1.6x10{sup -12} T-atoms/Li-atom at a sample, respectively. This standard deviation exceeds the expected deviation of 5 % in this program. It is presumed that the deviation of 10 % is caused mainly by the systematic and unknown errors in
More>>
Maekawa, Fujio;
Maekawa, Hiroshi
[1]
- Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; eds.
Citation Formats
Maekawa, Fujio, and Maekawa, Hiroshi.
Second international comparison on measuring techniques of tritium production rate for fusion neutronics experiments (ICMT-2).
Japan: N. p.,
1993.
Web.
Maekawa, Fujio, & Maekawa, Hiroshi.
Second international comparison on measuring techniques of tritium production rate for fusion neutronics experiments (ICMT-2).
Japan.
Maekawa, Fujio, and Maekawa, Hiroshi.
1993.
"Second international comparison on measuring techniques of tritium production rate for fusion neutronics experiments (ICMT-2)."
Japan.
@misc{etde_10150798,
title = {Second international comparison on measuring techniques of tritium production rate for fusion neutronics experiments (ICMT-2)}
author = {Maekawa, Fujio, and Maekawa, Hiroshi}
abstractNote = {An second international comparison on measuring techniques of tritium production rates for fusion neutronics experiments (ICMT-2) has been performed. The purpose is to evaluate the measurement accuracy of tritium production rates in the current measurement techniques. Two 14 MeV neutron source facilities, FNS at JAERI-Japan and LOTUS at EPFL-Switzerland, were used for this purpose. Nine groups out of seven countries participated in this program. A fusion simulated blanket assembly of simple-geometry was served as the test bed at each facility, in which Li-containing samples from the participants were irradiated in an uniform neutron field. The tritium production rates were determined by the participants using their own ways by using the liquid scintillation counting method. Tritiated water sample with unknown but the same concentration was also distributed and its concentration was measured to make a common reference. The standard deviation of measured tritium production rates among participants was about 10 % for both FNS and LOTUS irradiation levels: 4x10{sup -13} T-atoms/Li-atom and 1.6x10{sup -12} T-atoms/Li-atom at a sample, respectively. This standard deviation exceeds the expected deviation of 5 % in this program. It is presumed that the deviation of 10 % is caused mainly by the systematic and unknown errors in a process of tritium extraction from the irradiated samples depending on each organization. (author).}
place = {Japan}
year = {1993}
month = {Feb}
}
title = {Second international comparison on measuring techniques of tritium production rate for fusion neutronics experiments (ICMT-2)}
author = {Maekawa, Fujio, and Maekawa, Hiroshi}
abstractNote = {An second international comparison on measuring techniques of tritium production rates for fusion neutronics experiments (ICMT-2) has been performed. The purpose is to evaluate the measurement accuracy of tritium production rates in the current measurement techniques. Two 14 MeV neutron source facilities, FNS at JAERI-Japan and LOTUS at EPFL-Switzerland, were used for this purpose. Nine groups out of seven countries participated in this program. A fusion simulated blanket assembly of simple-geometry was served as the test bed at each facility, in which Li-containing samples from the participants were irradiated in an uniform neutron field. The tritium production rates were determined by the participants using their own ways by using the liquid scintillation counting method. Tritiated water sample with unknown but the same concentration was also distributed and its concentration was measured to make a common reference. The standard deviation of measured tritium production rates among participants was about 10 % for both FNS and LOTUS irradiation levels: 4x10{sup -13} T-atoms/Li-atom and 1.6x10{sup -12} T-atoms/Li-atom at a sample, respectively. This standard deviation exceeds the expected deviation of 5 % in this program. It is presumed that the deviation of 10 % is caused mainly by the systematic and unknown errors in a process of tritium extraction from the irradiated samples depending on each organization. (author).}
place = {Japan}
year = {1993}
month = {Feb}
}