You need JavaScript to view this

Development and application of a quasi-continuously working system for measuring the immission of acid air pollutants like HCl, NO{sub 2} and SO{sub 2} using an absorber tube; Entwicklung und Optimierung eines quasikontinuierlichen Immissions-Messverfahrens zur simultanen Bestimmung der sauren Luftinhaltsstoffe HCl, NO{sub 2} und SO{sub 2} mit einem Aktivsammler

Abstract

Main objective of this study during the report time is found to be the testing of different absorption materials for the simultaneous determination of acid gaseous pollutants like HCl, NO{sub 2} and SO{sub 2}. These materials - so-called active collectors - were examined in laboratory-scale experiments using gas mixtures with various concentrations of the pollutants which should be chemisorbed by the active collectors. After eluation of the active collector and ion chromatographical analysis of the solutions informations about the absorption/desorption rate are obtained. In most cases adsorption were tested on which amino-functional groups are deposited by chemical reaction. The amino-groups act as reactive sites for the chemisorption of the acid gases. It can be observed that all tested materials are suitable for the measurement of HCl and SO{sub 2}. Additionally some types of absorption materials are effective for the simultaneous absorption of HCl, SO{sub 2} and NO{sub 2}. (orig.). 25 figs., 21 tabs., 66 refs.
Authors:
Weisweiler, W; [1]  Creutznacher, H; [1]  Wien, F [1] 
  1. Karlsruhe Univ. (T.H.) (Germany). Inst. fuer Chemische Technik
Publication Date:
Oct 01, 1993
Product Type:
Technical Report
Report Number:
KFK-PEF-112
Reference Number:
SCA: 540120; 400102; PA: DEN-94:0F5943; EDB-94:077154; ERA-19:019543; NTS-94:023597; SN: 94001202905
Resource Relation:
Other Information: PBD: Oct 1993
Subject:
54 ENVIRONMENTAL SCIENCES; 37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; AIR POLLUTION MONITORING; OPTIMIZATION; AIR SAMPLERS; NITROGEN DIOXIDE; SULFUR DIOXIDE; HYDROCHLORIC ACID; QUANTITATIVE CHEMICAL ANALYSIS; SORPTION; DESORPTION; 540120; 400102; CHEMICALS MONITORING AND TRANSPORT; CHEMICAL AND SPECTRAL PROCEDURES
Sponsoring Organizations:
Land Baden-Wuerttemberg, Stuttgart (Germany); Commission of the European Communities, Brussels (Belgium)
OSTI ID:
10150572
Research Organizations:
Kernforschungszentrum Karlsruhe GmbH (Germany). Projekt Europaeisches Forschungszentrum fuer Massnahmen zur Luftreinhaltung (PEF)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Journal ID: ISSN 0931-2749; Other: ON: DE94766043; CNN: Contract PEF 91/003/2; TRN: DE94F5943
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
77 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Weisweiler, W, Creutznacher, H, and Wien, F. Development and application of a quasi-continuously working system for measuring the immission of acid air pollutants like HCl, NO{sub 2} and SO{sub 2} using an absorber tube; Entwicklung und Optimierung eines quasikontinuierlichen Immissions-Messverfahrens zur simultanen Bestimmung der sauren Luftinhaltsstoffe HCl, NO{sub 2} und SO{sub 2} mit einem Aktivsammler. Germany: N. p., 1993. Web.
Weisweiler, W, Creutznacher, H, & Wien, F. Development and application of a quasi-continuously working system for measuring the immission of acid air pollutants like HCl, NO{sub 2} and SO{sub 2} using an absorber tube; Entwicklung und Optimierung eines quasikontinuierlichen Immissions-Messverfahrens zur simultanen Bestimmung der sauren Luftinhaltsstoffe HCl, NO{sub 2} und SO{sub 2} mit einem Aktivsammler. Germany.
Weisweiler, W, Creutznacher, H, and Wien, F. 1993. "Development and application of a quasi-continuously working system for measuring the immission of acid air pollutants like HCl, NO{sub 2} and SO{sub 2} using an absorber tube; Entwicklung und Optimierung eines quasikontinuierlichen Immissions-Messverfahrens zur simultanen Bestimmung der sauren Luftinhaltsstoffe HCl, NO{sub 2} und SO{sub 2} mit einem Aktivsammler." Germany.
@misc{etde_10150572,
title = {Development and application of a quasi-continuously working system for measuring the immission of acid air pollutants like HCl, NO{sub 2} and SO{sub 2} using an absorber tube; Entwicklung und Optimierung eines quasikontinuierlichen Immissions-Messverfahrens zur simultanen Bestimmung der sauren Luftinhaltsstoffe HCl, NO{sub 2} und SO{sub 2} mit einem Aktivsammler}
author = {Weisweiler, W, Creutznacher, H, and Wien, F}
abstractNote = {Main objective of this study during the report time is found to be the testing of different absorption materials for the simultaneous determination of acid gaseous pollutants like HCl, NO{sub 2} and SO{sub 2}. These materials - so-called active collectors - were examined in laboratory-scale experiments using gas mixtures with various concentrations of the pollutants which should be chemisorbed by the active collectors. After eluation of the active collector and ion chromatographical analysis of the solutions informations about the absorption/desorption rate are obtained. In most cases adsorption were tested on which amino-functional groups are deposited by chemical reaction. The amino-groups act as reactive sites for the chemisorption of the acid gases. It can be observed that all tested materials are suitable for the measurement of HCl and SO{sub 2}. Additionally some types of absorption materials are effective for the simultaneous absorption of HCl, SO{sub 2} and NO{sub 2}. (orig.). 25 figs., 21 tabs., 66 refs.}
place = {Germany}
year = {1993}
month = {Oct}
}