Abstract
In this paper the requirements and the main features of the Electron Cyclotron Emission (ECE) diagnostic for the Frascati Tokamak Upgrade (FTU) are outlined. The realization of the light collection system and of the Fourier transform spectrometer are described. Some plama data are reported to illustrate the diagnostic work. The ECE diagnostic system has been realized using mixed waveguide-optical techniques for light collection. Spatial resolution is 2 centimeters HWHM, spectral resolution 5 GHz and time resolution 5 ms (potentially less); sensitivity is such that signal-carried noise dominates.
Citation Formats
Buratti, P, Tudisco, O, and Zerbini, M.
Electron cyclotron emission diagnostic for electron temperature profiles measurement on FTU Tokamak.
Italy: N. p.,
1991.
Web.
Buratti, P, Tudisco, O, & Zerbini, M.
Electron cyclotron emission diagnostic for electron temperature profiles measurement on FTU Tokamak.
Italy.
Buratti, P, Tudisco, O, and Zerbini, M.
1991.
"Electron cyclotron emission diagnostic for electron temperature profiles measurement on FTU Tokamak."
Italy.
@misc{etde_10150490,
title = {Electron cyclotron emission diagnostic for electron temperature profiles measurement on FTU Tokamak}
author = {Buratti, P, Tudisco, O, and Zerbini, M}
abstractNote = {In this paper the requirements and the main features of the Electron Cyclotron Emission (ECE) diagnostic for the Frascati Tokamak Upgrade (FTU) are outlined. The realization of the light collection system and of the Fourier transform spectrometer are described. Some plama data are reported to illustrate the diagnostic work. The ECE diagnostic system has been realized using mixed waveguide-optical techniques for light collection. Spatial resolution is 2 centimeters HWHM, spectral resolution 5 GHz and time resolution 5 ms (potentially less); sensitivity is such that signal-carried noise dominates.}
place = {Italy}
year = {1991}
month = {Dec}
}
title = {Electron cyclotron emission diagnostic for electron temperature profiles measurement on FTU Tokamak}
author = {Buratti, P, Tudisco, O, and Zerbini, M}
abstractNote = {In this paper the requirements and the main features of the Electron Cyclotron Emission (ECE) diagnostic for the Frascati Tokamak Upgrade (FTU) are outlined. The realization of the light collection system and of the Fourier transform spectrometer are described. Some plama data are reported to illustrate the diagnostic work. The ECE diagnostic system has been realized using mixed waveguide-optical techniques for light collection. Spatial resolution is 2 centimeters HWHM, spectral resolution 5 GHz and time resolution 5 ms (potentially less); sensitivity is such that signal-carried noise dominates.}
place = {Italy}
year = {1991}
month = {Dec}
}