You need JavaScript to view this

On the use of time resolved laser-induced spectrofluorometry in the nuclear fuel cycle

Abstract

Time Resolved Laser-Induced Spectrofluorometry (TRLIS) has been used for actinides trace analysis and complexation analysis in the nuclear fuel cycle. Results obtained in the different fields such as in geology, in the Purex process, in the environment, in the medical and in waste storage assessment are presented. 4 figs., 6 refs.
Publication Date:
Dec 31, 1991
Product Type:
Conference
Report Number:
CEA-CONF-10767; CONF-910534-
Reference Number:
SCA: 400102; 050800; PA: FRD-92:001374; SN: 92000757268
Resource Relation:
Conference: 13. annual symposium of the European Safeguards Research and Development Associations (ESARDA),Avignon (France),14-16 May 1991; Other Information: PBD: 1991
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; ACTINIDES; FLUORESCENCE SPECTROSCOPY; LASER SPECTROSCOPY; TIME RESOLUTION; TRACE AMOUNTS; USES; 400102; 050800; CHEMICAL AND SPECTRAL PROCEDURES; SPENT FUELS REPROCESSING
OSTI ID:
10150038
Research Organizations:
CEA Centre d`Etudes de la Vallee du Rhone, 30 - Marcoule (France). Direction du Cycle du Combustible
Country of Origin:
France
Language:
English
Other Identifying Numbers:
Other: ON: DE92526972; TRN: FR9201374
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
FRN
Size:
4 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Moulin, C, Decambox, P, Mauchien, P, Davin, T, and Pradel, B. On the use of time resolved laser-induced spectrofluorometry in the nuclear fuel cycle. France: N. p., 1991. Web.
Moulin, C, Decambox, P, Mauchien, P, Davin, T, & Pradel, B. On the use of time resolved laser-induced spectrofluorometry in the nuclear fuel cycle. France.
Moulin, C, Decambox, P, Mauchien, P, Davin, T, and Pradel, B. 1991. "On the use of time resolved laser-induced spectrofluorometry in the nuclear fuel cycle." France.
@misc{etde_10150038,
title = {On the use of time resolved laser-induced spectrofluorometry in the nuclear fuel cycle}
author = {Moulin, C, Decambox, P, Mauchien, P, Davin, T, and Pradel, B}
abstractNote = {Time Resolved Laser-Induced Spectrofluorometry (TRLIS) has been used for actinides trace analysis and complexation analysis in the nuclear fuel cycle. Results obtained in the different fields such as in geology, in the Purex process, in the environment, in the medical and in waste storage assessment are presented. 4 figs., 6 refs.}
place = {France}
year = {1991}
month = {Dec}
}