Examination of the defects of the Ispra vessel A

Abstract

The Department END of FRAMATOME has participated together with other European laboratories in applying new non-destructive control techniques on the test pressure vessels (scale 1:5) at JRC Ispra. The works carried out refer to the characterization and the dimensioning of ultrasonic (USO) signals by respective data processing methods. The results have been confronted with the interpretations of the USO operator. The examinations were performed in three separate measurement campaigns during fatigue cycling and thermal treatment of one of the vessels. They allowed to evaluate the methods applied and the operator conditions with regard to the set objectives
Authors:
Dugue, C [1] 
  1. Societe Franco-Americaine de Constructions Atomiques (FRAMATOME), 92 - Courbevoie (France)
Publication Date:
Dec 31, 1991
Product Type:
Technical Report
Report Number:
EUR-13839
Reference Number:
SCA: 220200; PA: FRD-92:001797; SN: 92000747583
Resource Relation:
Other Information: PBD: 1991
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; PWR TYPE REACTORS; REACTOR VESSELS; ULTRASONIC TESTING; TEST FACILITIES; ALGORITHMS; DATA PROCESSING; DEFECTS; THERMAL FATIGUE; 220200; COMPONENTS AND ACCESSORIES
OSTI ID:
10148523
Research Organizations:
Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking
Country of Origin:
France
Language:
English
Other Identifying Numbers:
Other: ON: TI92523931; CNN: Contract 3011-86-07 ELISPF; TRN: FR9201797
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
FRN
Size:
50 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Dugue, C. Examination of the defects of the Ispra vessel A. France: N. p., 1991. Web.
Dugue, C. Examination of the defects of the Ispra vessel A. France.
Dugue, C. 1991. "Examination of the defects of the Ispra vessel A." France.
@misc{etde_10148523,
title = {Examination of the defects of the Ispra vessel A}
author = {Dugue, C}
abstractNote = {The Department END of FRAMATOME has participated together with other European laboratories in applying new non-destructive control techniques on the test pressure vessels (scale 1:5) at JRC Ispra. The works carried out refer to the characterization and the dimensioning of ultrasonic (USO) signals by respective data processing methods. The results have been confronted with the interpretations of the USO operator. The examinations were performed in three separate measurement campaigns during fatigue cycling and thermal treatment of one of the vessels. They allowed to evaluate the methods applied and the operator conditions with regard to the set objectives}
place = {France}
year = {1991}