Energy saving, consultancy and training in Latvia. Energy savings in public buildings. Audit of: Hospital no. 7, Riga. Final report

Abstract

The hospital no 7 is only about 10 years old but there are some improvements to be done if the building envelope and the technical services shall gain an acceptable level from an energy point of view. To improve the building envelope it is suggested that the floors over the basement should be insulated underneath with at least 100 mm hard mineral wool, the roof (floor in the technical room) should be insulated with at least 100 mm of mineral wool, insulation with a waterproof covering should be fitted on the outside of the spandrel panels and all windows should be adjusted and/or repaired, fitted with weather seals and the woodwork treated for weather protection. (au).
Publication Date:
Oct 01, 1992
Product Type:
Technical Report
Report Number:
NEI-DK-1115
Reference Number:
SCA: 320100; PA: DK-93:001218; SN: 93000980969
Resource Relation:
Other Information: PBD: Oct 1992
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; EASTERN EUROPE; HOSPITALS; ENERGY CONSERVATION; RETROFITTING; THERMAL INSULATION; OPTIMIZATION; 320100; BUILDINGS
OSTI ID:
10148480
Research Organizations:
Birch and Krogboe Overseas, Consulting Engineers and Planners ApS, Virum (Denmark)
Country of Origin:
Denmark
Language:
English
Other Identifying Numbers:
Other: ON: DE93784718; CNN: Contract IMOe-427; TRN: DK9301218
Availability:
OSTI; NTIS
Submitting Site:
DK
Size:
20 p.
Announcement Date:
Jul 05, 2005

Citation Formats

None. Energy saving, consultancy and training in Latvia. Energy savings in public buildings. Audit of: Hospital no. 7, Riga. Final report. Denmark: N. p., 1992. Web.
None. Energy saving, consultancy and training in Latvia. Energy savings in public buildings. Audit of: Hospital no. 7, Riga. Final report. Denmark.
None. 1992. "Energy saving, consultancy and training in Latvia. Energy savings in public buildings. Audit of: Hospital no. 7, Riga. Final report." Denmark.
@misc{etde_10148480,
title = {Energy saving, consultancy and training in Latvia. Energy savings in public buildings. Audit of: Hospital no. 7, Riga. Final report}
author = {None}
abstractNote = {The hospital no 7 is only about 10 years old but there are some improvements to be done if the building envelope and the technical services shall gain an acceptable level from an energy point of view. To improve the building envelope it is suggested that the floors over the basement should be insulated underneath with at least 100 mm hard mineral wool, the roof (floor in the technical room) should be insulated with at least 100 mm of mineral wool, insulation with a waterproof covering should be fitted on the outside of the spandrel panels and all windows should be adjusted and/or repaired, fitted with weather seals and the woodwork treated for weather protection. (au).}
place = {Denmark}
year = {1992}
month = {Oct}
}