You need JavaScript to view this

Detection of personnel contamination amounting to the limit values of surface contaminations according to annex IX Radiation Protection Ordinance for articles, clothing and textiles outside controlled areas; Erfassung von Personenkontaminationen in Hoehe der Grenzwerte der Flaechenkontamination nach Anlage IX StrlSchV fuer Gegenstaende, Kleidung und Waesche ausserhalb von betrieblichen Ueberwachungsbereichen

Abstract

The surface response sensitivity for detecting contamination by 589 radionuclides and 44 radionuclide mixtures is assessed and compared with the minimum surface response sensitivity which is required to detect surface contaminations amounting to the limit values for articles, clothing and textiles outside controlled areas. To calculate the surface response sensitivity for detection of contamination by the considered approx. 600 nuclides emitting {alpha}, {beta}, {gamma} radiation and conversion electrons with different energies, the surface response sensitivity of a sufficiently large number of appropriate nuclides would have to be known. That is not the case. The calculations performed are based only on several experimental values. Therefore the surface response sensitivity can only be assessed. Such assessments are conservative, that means that the surface response sensitivity of good contamination monitors may be slightly higher. (orig./HP). [Deutsch] Das Oberflaechenansprechvermoegen zum Kontaminationsnachweis fuer 589 Radionuklide und 44 Radionuklidgemische wird abgeschaetzt und mit dem minimalen Oberflaechenansprechvermoegen, das zum Nachweis von Flaechenkontaminationen in Hoehe der Grenzwerte fuer Gegenstaende, Kleidung und Waesche ausserhalb von betrieblichen Ueberwachungsbereichen erforderlich ist, verglichen. Zur Berechnung des Oberflaechenansprechvermoegens zum Kontaminationsnachweis fuer die betrachteten ca. 600 Nuklide, die {alpha}, {beta}, {gamma}-Strahlung und Konversionselektronen unterschiedlicher Energie aussenden, muesste das Oberflaechenansprechvermoegen fuer eine hinreichend grosse Anzahl  More>>
Authors:
Heinzelmann, M; [1]  Schnepel, G H [2] 
  1. Forschungszentrum Juelich (Germany)
  2. Bundesamt fuer Strahlenschutz, Bonn (Germany)
Publication Date:
Sep 01, 1992
Product Type:
Technical Report
Report Number:
Juel-2678
Reference Number:
SCA: 440101; 560101; PA: DEN-93:005373; SN: 93000982845
Resource Relation:
Other Information: PBD: Sep 1992
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 61 RADIATION PROTECTION AND DOSIMETRY; SURFACE CONTAMINATION MONITORS; PERSONNEL MONITORING; RESPONSE FUNCTIONS; SENSITIVITY; MAXIMUM ACCEPTABLE CONTAMINATION; HANDS; CLOTHING; TEXTILES; FEET; ACTIVITY LEVELS; MAXIMUM PERMISSIBLE ACTIVITY; PROPORTIONAL COUNTERS; ALPHA DETECTION; BETA DETECTION; GAMMA DETECTION; ELECTRON DETECTION; 440101; 560101; GENERAL DETECTORS OR MONITORS AND RADIOMETRIC INSTRUMENTS; DOSIMETRY AND MONITORING
OSTI ID:
10148205
Research Organizations:
Forschungszentrum Juelich GmbH (Germany). Abt. Sicherheit und Strahlenschutz
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE93785895; TRN: DE9305373
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
78 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Heinzelmann, M, and Schnepel, G H. Detection of personnel contamination amounting to the limit values of surface contaminations according to annex IX Radiation Protection Ordinance for articles, clothing and textiles outside controlled areas; Erfassung von Personenkontaminationen in Hoehe der Grenzwerte der Flaechenkontamination nach Anlage IX StrlSchV fuer Gegenstaende, Kleidung und Waesche ausserhalb von betrieblichen Ueberwachungsbereichen. Germany: N. p., 1992. Web.
Heinzelmann, M, & Schnepel, G H. Detection of personnel contamination amounting to the limit values of surface contaminations according to annex IX Radiation Protection Ordinance for articles, clothing and textiles outside controlled areas; Erfassung von Personenkontaminationen in Hoehe der Grenzwerte der Flaechenkontamination nach Anlage IX StrlSchV fuer Gegenstaende, Kleidung und Waesche ausserhalb von betrieblichen Ueberwachungsbereichen. Germany.
Heinzelmann, M, and Schnepel, G H. 1992. "Detection of personnel contamination amounting to the limit values of surface contaminations according to annex IX Radiation Protection Ordinance for articles, clothing and textiles outside controlled areas; Erfassung von Personenkontaminationen in Hoehe der Grenzwerte der Flaechenkontamination nach Anlage IX StrlSchV fuer Gegenstaende, Kleidung und Waesche ausserhalb von betrieblichen Ueberwachungsbereichen." Germany.
@misc{etde_10148205,
title = {Detection of personnel contamination amounting to the limit values of surface contaminations according to annex IX Radiation Protection Ordinance for articles, clothing and textiles outside controlled areas; Erfassung von Personenkontaminationen in Hoehe der Grenzwerte der Flaechenkontamination nach Anlage IX StrlSchV fuer Gegenstaende, Kleidung und Waesche ausserhalb von betrieblichen Ueberwachungsbereichen}
author = {Heinzelmann, M, and Schnepel, G H}
abstractNote = {The surface response sensitivity for detecting contamination by 589 radionuclides and 44 radionuclide mixtures is assessed and compared with the minimum surface response sensitivity which is required to detect surface contaminations amounting to the limit values for articles, clothing and textiles outside controlled areas. To calculate the surface response sensitivity for detection of contamination by the considered approx. 600 nuclides emitting {alpha}, {beta}, {gamma} radiation and conversion electrons with different energies, the surface response sensitivity of a sufficiently large number of appropriate nuclides would have to be known. That is not the case. The calculations performed are based only on several experimental values. Therefore the surface response sensitivity can only be assessed. Such assessments are conservative, that means that the surface response sensitivity of good contamination monitors may be slightly higher. (orig./HP). [Deutsch] Das Oberflaechenansprechvermoegen zum Kontaminationsnachweis fuer 589 Radionuklide und 44 Radionuklidgemische wird abgeschaetzt und mit dem minimalen Oberflaechenansprechvermoegen, das zum Nachweis von Flaechenkontaminationen in Hoehe der Grenzwerte fuer Gegenstaende, Kleidung und Waesche ausserhalb von betrieblichen Ueberwachungsbereichen erforderlich ist, verglichen. Zur Berechnung des Oberflaechenansprechvermoegens zum Kontaminationsnachweis fuer die betrachteten ca. 600 Nuklide, die {alpha}, {beta}, {gamma}-Strahlung und Konversionselektronen unterschiedlicher Energie aussenden, muesste das Oberflaechenansprechvermoegen fuer eine hinreichend grosse Anzahl geeigneter Nuklide bekannt sein. Das ist nicht der Fall. Die durchgefuehrten Rechnungen beruhen nur auf einigen experimentellen Werten. Deswegen kann das Oberflaechenansprechvermoegen nur abgeschaetzt werden. Diese Abschaetzungen sind konservativ, d.h. das Oberflaechenansprechvermoegen guter Kontaminationsmonitore kann geringfuegig groesser sein. (orig./HP).}
place = {Germany}
year = {1992}
month = {Sep}
}