Abstract
In assessing overhead power transmission line design and planning criteria for the optimization of visual impact, safety and the reduction of electro magnetic disturbance effects, this paper reviews the research findings of ENEL, the Italian Electricity Board. The on-going research activities involve theoretical calculations and laboratory performance tests to determine the best compact configurations for 380 kV lines. The parameters under examination include: insulator spacing, sizing and salt fog resistivity; allowable overvoltages; maximum line length; behaviour in lightning conditions; radio and acoustics disturbances.
Citation Formats
Deponti, F, Fini, G P, Porrino, A, and Rosa, F.
Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination; La Riduzione di ingombro delle linee di trasmissione nei confronti dei vincoli dielettrici e dei disturbi per effetto corona.
Italy: N. p.,
1992.
Web.
Deponti, F, Fini, G P, Porrino, A, & Rosa, F.
Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination; La Riduzione di ingombro delle linee di trasmissione nei confronti dei vincoli dielettrici e dei disturbi per effetto corona.
Italy.
Deponti, F, Fini, G P, Porrino, A, and Rosa, F.
1992.
"Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination; La Riduzione di ingombro delle linee di trasmissione nei confronti dei vincoli dielettrici e dei disturbi per effetto corona."
Italy.
@misc{etde_10147092,
title = {Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination; La Riduzione di ingombro delle linee di trasmissione nei confronti dei vincoli dielettrici e dei disturbi per effetto corona}
author = {Deponti, F, Fini, G P, Porrino, A, and Rosa, F}
abstractNote = {In assessing overhead power transmission line design and planning criteria for the optimization of visual impact, safety and the reduction of electro magnetic disturbance effects, this paper reviews the research findings of ENEL, the Italian Electricity Board. The on-going research activities involve theoretical calculations and laboratory performance tests to determine the best compact configurations for 380 kV lines. The parameters under examination include: insulator spacing, sizing and salt fog resistivity; allowable overvoltages; maximum line length; behaviour in lightning conditions; radio and acoustics disturbances.}
place = {Italy}
year = {1992}
month = {Jun}
}
title = {Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination; La Riduzione di ingombro delle linee di trasmissione nei confronti dei vincoli dielettrici e dei disturbi per effetto corona}
author = {Deponti, F, Fini, G P, Porrino, A, and Rosa, F}
abstractNote = {In assessing overhead power transmission line design and planning criteria for the optimization of visual impact, safety and the reduction of electro magnetic disturbance effects, this paper reviews the research findings of ENEL, the Italian Electricity Board. The on-going research activities involve theoretical calculations and laboratory performance tests to determine the best compact configurations for 380 kV lines. The parameters under examination include: insulator spacing, sizing and salt fog resistivity; allowable overvoltages; maximum line length; behaviour in lightning conditions; radio and acoustics disturbances.}
place = {Italy}
year = {1992}
month = {Jun}
}