Abstract
The development project of very compact ECR Ion Source (ECRIS) connected to the GANIL consists of post-accelerating radioactive ions with a cyclotron to energies between 2 MeV/A and 20 MeV/A. The main goal of source development is to adapt classical ECRIS to the production of multicharged and radioactive ions. Different experiments and studies are described which are underway at GANIL in order to design a new operational ECRIS totally adapted to the on-line production of gaseous and metallic radioactive ions. Latest results obtained with the ultra compact and purely permanent magnets ECRIS called NANOGAN are described. (R.P.) 9 refs., 20 figs., 2 tabs.
Sortais, P;
Bisch, M;
Bricault, P;
Leherissier, P;
Lewitowitz, M;
Leroy, R;
[1]
Putaux, J C;
Obert, J;
[2]
Liang, C F;
Paris, P
[3]
- Grand Accelerateur National d`Ions Lourds (GANIL), 14 - Caen (France)
- Paris-11 Univ., 91 - Orsay (France). Inst. de Physique Nucleaire
- Paris-11 Univ., 91 - Orsay (France). Centre de Spectrometrie Nucleaire et de Spectrometrie de Masse; and others
Citation Formats
Sortais, P, Bisch, M, Bricault, P, Leherissier, P, Lewitowitz, M, Leroy, R, Putaux, J C, Obert, J, Liang, C F, and Paris, P.
NANOGAN: An ultra compact ECRIS for on-line and high voltage applications.
France: N. p.,
1993.
Web.
Sortais, P, Bisch, M, Bricault, P, Leherissier, P, Lewitowitz, M, Leroy, R, Putaux, J C, Obert, J, Liang, C F, & Paris, P.
NANOGAN: An ultra compact ECRIS for on-line and high voltage applications.
France.
Sortais, P, Bisch, M, Bricault, P, Leherissier, P, Lewitowitz, M, Leroy, R, Putaux, J C, Obert, J, Liang, C F, and Paris, P.
1993.
"NANOGAN: An ultra compact ECRIS for on-line and high voltage applications."
France.
@misc{etde_10146939,
title = {NANOGAN: An ultra compact ECRIS for on-line and high voltage applications}
author = {Sortais, P, Bisch, M, Bricault, P, Leherissier, P, Lewitowitz, M, Leroy, R, Putaux, J C, Obert, J, Liang, C F, and Paris, P}
abstractNote = {The development project of very compact ECR Ion Source (ECRIS) connected to the GANIL consists of post-accelerating radioactive ions with a cyclotron to energies between 2 MeV/A and 20 MeV/A. The main goal of source development is to adapt classical ECRIS to the production of multicharged and radioactive ions. Different experiments and studies are described which are underway at GANIL in order to design a new operational ECRIS totally adapted to the on-line production of gaseous and metallic radioactive ions. Latest results obtained with the ultra compact and purely permanent magnets ECRIS called NANOGAN are described. (R.P.) 9 refs., 20 figs., 2 tabs.}
place = {France}
year = {1993}
month = {Dec}
}
title = {NANOGAN: An ultra compact ECRIS for on-line and high voltage applications}
author = {Sortais, P, Bisch, M, Bricault, P, Leherissier, P, Lewitowitz, M, Leroy, R, Putaux, J C, Obert, J, Liang, C F, and Paris, P}
abstractNote = {The development project of very compact ECR Ion Source (ECRIS) connected to the GANIL consists of post-accelerating radioactive ions with a cyclotron to energies between 2 MeV/A and 20 MeV/A. The main goal of source development is to adapt classical ECRIS to the production of multicharged and radioactive ions. Different experiments and studies are described which are underway at GANIL in order to design a new operational ECRIS totally adapted to the on-line production of gaseous and metallic radioactive ions. Latest results obtained with the ultra compact and purely permanent magnets ECRIS called NANOGAN are described. (R.P.) 9 refs., 20 figs., 2 tabs.}
place = {France}
year = {1993}
month = {Dec}
}