Calibration and application of a HPGe gamma spectrometer for in-situ measurements

Abstract

The principle and methods of the calibration for an in-situ {gamma} spectrometer are introduced. The calibration for a portable HPGe {gamma} spectrometer has been completed. The N{sub f}/A(peak count rate per unit activity in soil) and N{sub f}/D(peak count rate per unit absorbed dose rate in the air) are listed. The uncertainties of the calibration factors are estimated. The in-situ measurements have been carried out in surroundings near the nuclear facilities and the data are compared with those measured by other methods.
Authors:
Xuefu, Xiao; Qingyu, Yue [1] 
  1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy
Publication Date:
Feb 01, 1992
Product Type:
Technical Report
Report Number:
CNIC-00565; IAE-0097.
Reference Number:
SCA: 440103; PA: AIX-24:039112; SN: 93000980082
Resource Relation:
Other Information: PBD: Feb 1992
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; GAMMA SPECTROMETERS; CALIBRATION; HIGH-PURITY GE DETECTORS; ACTIVITY LEVELS; AIR; COMPARATIVE EVALUATIONS; RADIOACTIVITY; SOILS; USES; 440103; NUCLEAR SPECTROSCOPIC INSTRUMENTATION
OSTI ID:
10145285
Research Organizations:
China Nuclear Information Centre, Beijing, BJ (China)
Country of Origin:
China
Language:
Chinese
Other Identifying Numbers:
Other: ON: DE93623855; TRN: CN9300206039112
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
[18] p.
Announcement Date:
Jul 05, 2005

Citation Formats

Xuefu, Xiao, and Qingyu, Yue. Calibration and application of a HPGe gamma spectrometer for in-situ measurements. China: N. p., 1992. Web.
Xuefu, Xiao, & Qingyu, Yue. Calibration and application of a HPGe gamma spectrometer for in-situ measurements. China.
Xuefu, Xiao, and Qingyu, Yue. 1992. "Calibration and application of a HPGe gamma spectrometer for in-situ measurements." China.
@misc{etde_10145285,
title = {Calibration and application of a HPGe gamma spectrometer for in-situ measurements}
author = {Xuefu, Xiao, and Qingyu, Yue}
abstractNote = {The principle and methods of the calibration for an in-situ {gamma} spectrometer are introduced. The calibration for a portable HPGe {gamma} spectrometer has been completed. The N{sub f}/A(peak count rate per unit activity in soil) and N{sub f}/D(peak count rate per unit absorbed dose rate in the air) are listed. The uncertainties of the calibration factors are estimated. The in-situ measurements have been carried out in surroundings near the nuclear facilities and the data are compared with those measured by other methods.}
place = {China}
year = {1992}
month = {Feb}
}