Abstract
A reactor core monitoring system having the function of early detection of boiling in the coolant channels of research reactors with MTR-type fuel is introduced. The system is based on the on-line analysis of signals of various ex-core and in-core neutron detectors. Early detection of coolant boiling cannot be accomplished by the evaluation of the DC components of these detectors in a number of practically important cases of boiling anomaly. It is shown that the noise component of the available neutron detector signals can be used for the detection of boiling in these cases. Experiments have been carried out at a boiling setup in the research reactor HOR of the Interfaculty Reactor Institute, Technical University of Delft, The Netherlands. (author). 8 refs., 11 figs.
Kozma, R;
Turkcan, E;
Verhoef, J P
[1]
- Netherlands Energy Research Foundation (ECN), Petten (Netherlands)
Citation Formats
Kozma, R, Turkcan, E, and Verhoef, J P.
Early detection of coolant boiling in research reactors with MTR-type fuel.
Netherlands: N. p.,
1992.
Web.
Kozma, R, Turkcan, E, & Verhoef, J P.
Early detection of coolant boiling in research reactors with MTR-type fuel.
Netherlands.
Kozma, R, Turkcan, E, and Verhoef, J P.
1992.
"Early detection of coolant boiling in research reactors with MTR-type fuel."
Netherlands.
@misc{etde_10145251,
title = {Early detection of coolant boiling in research reactors with MTR-type fuel}
author = {Kozma, R, Turkcan, E, and Verhoef, J P}
abstractNote = {A reactor core monitoring system having the function of early detection of boiling in the coolant channels of research reactors with MTR-type fuel is introduced. The system is based on the on-line analysis of signals of various ex-core and in-core neutron detectors. Early detection of coolant boiling cannot be accomplished by the evaluation of the DC components of these detectors in a number of practically important cases of boiling anomaly. It is shown that the noise component of the available neutron detector signals can be used for the detection of boiling in these cases. Experiments have been carried out at a boiling setup in the research reactor HOR of the Interfaculty Reactor Institute, Technical University of Delft, The Netherlands. (author). 8 refs., 11 figs.}
place = {Netherlands}
year = {1992}
month = {Oct}
}
title = {Early detection of coolant boiling in research reactors with MTR-type fuel}
author = {Kozma, R, Turkcan, E, and Verhoef, J P}
abstractNote = {A reactor core monitoring system having the function of early detection of boiling in the coolant channels of research reactors with MTR-type fuel is introduced. The system is based on the on-line analysis of signals of various ex-core and in-core neutron detectors. Early detection of coolant boiling cannot be accomplished by the evaluation of the DC components of these detectors in a number of practically important cases of boiling anomaly. It is shown that the noise component of the available neutron detector signals can be used for the detection of boiling in these cases. Experiments have been carried out at a boiling setup in the research reactor HOR of the Interfaculty Reactor Institute, Technical University of Delft, The Netherlands. (author). 8 refs., 11 figs.}
place = {Netherlands}
year = {1992}
month = {Oct}
}