Abstract
The computer automated PC-based acquisition system for nuclear radiation multidetector measurement and real time data processing has been constructed. The system enables to measure 1 K-. 2 K-, 4 K-or 8 K-channel separate spectra from up to eight detectors in the common dual-port 256 K word memory. (author). 3 refs., 2 figs.
Citation Formats
Ofengenden, R G, Berezin, F N, Kisurin, V A, Lyubanskij, G B, Maznyj, I A, Sidorenko, V A, and Shalejko, M A.
The system for nuclear radiation multidetector automatic measurements with real time data processing; Sistema dlya mnogodetektornykh avtomatizirovannykh izmerenij yadernykh izluchenij s obrabotkoj informatsii v real`nom vremeni.
Ukraine: N. p.,
1993.
Web.
Ofengenden, R G, Berezin, F N, Kisurin, V A, Lyubanskij, G B, Maznyj, I A, Sidorenko, V A, & Shalejko, M A.
The system for nuclear radiation multidetector automatic measurements with real time data processing; Sistema dlya mnogodetektornykh avtomatizirovannykh izmerenij yadernykh izluchenij s obrabotkoj informatsii v real`nom vremeni.
Ukraine.
Ofengenden, R G, Berezin, F N, Kisurin, V A, Lyubanskij, G B, Maznyj, I A, Sidorenko, V A, and Shalejko, M A.
1993.
"The system for nuclear radiation multidetector automatic measurements with real time data processing; Sistema dlya mnogodetektornykh avtomatizirovannykh izmerenij yadernykh izluchenij s obrabotkoj informatsii v real`nom vremeni."
Ukraine.
@misc{etde_10144828,
title = {The system for nuclear radiation multidetector automatic measurements with real time data processing; Sistema dlya mnogodetektornykh avtomatizirovannykh izmerenij yadernykh izluchenij s obrabotkoj informatsii v real`nom vremeni}
author = {Ofengenden, R G, Berezin, F N, Kisurin, V A, Lyubanskij, G B, Maznyj, I A, Sidorenko, V A, and Shalejko, M A}
abstractNote = {The computer automated PC-based acquisition system for nuclear radiation multidetector measurement and real time data processing has been constructed. The system enables to measure 1 K-. 2 K-, 4 K-or 8 K-channel separate spectra from up to eight detectors in the common dual-port 256 K word memory. (author). 3 refs., 2 figs.}
place = {Ukraine}
year = {1993}
month = {Dec}
}
title = {The system for nuclear radiation multidetector automatic measurements with real time data processing; Sistema dlya mnogodetektornykh avtomatizirovannykh izmerenij yadernykh izluchenij s obrabotkoj informatsii v real`nom vremeni}
author = {Ofengenden, R G, Berezin, F N, Kisurin, V A, Lyubanskij, G B, Maznyj, I A, Sidorenko, V A, and Shalejko, M A}
abstractNote = {The computer automated PC-based acquisition system for nuclear radiation multidetector measurement and real time data processing has been constructed. The system enables to measure 1 K-. 2 K-, 4 K-or 8 K-channel separate spectra from up to eight detectors in the common dual-port 256 K word memory. (author). 3 refs., 2 figs.}
place = {Ukraine}
year = {1993}
month = {Dec}
}