Abstract
Ten kindergartens were investigated in order to determine the pollution load from material sources, ventilations systems and persons. Measurements were based on judgements given by a trained panel of experts, measurements of air change, moisture and air movement as well as of carbon dioxide, carbon monoxide and total volatile organic vapours. With the help of questionnaires the extent and characteristics of irritating symptoms experienced by personnel and the children were examined. Average pollution loads were on average 0.07 olf (2 square meters floor area) from materials, - 0.32 olf (2 square meters floor area) from ventilation systems, and 0.38 olf from persons. Pollution from 244 children aged 3-6 years the extent of pollution was 1.2 olf per child, in relation to the children`s natural niveau of activity. (AB) (12 refs.).
Citation Formats
Pejtersen, J, Clausen, G, and Fanger, P O.
Ventilation needs in buildings - establishment of a rational basis for demands from the authorities. Phase 2. Children`s institutions; Ventilationsbehov i bygninger - opstilling af rationelt grundlag for myndighedskrav. Fase 2. Boerneinstitutioner.
Denmark: N. p.,
1991.
Web.
Pejtersen, J, Clausen, G, & Fanger, P O.
Ventilation needs in buildings - establishment of a rational basis for demands from the authorities. Phase 2. Children`s institutions; Ventilationsbehov i bygninger - opstilling af rationelt grundlag for myndighedskrav. Fase 2. Boerneinstitutioner.
Denmark.
Pejtersen, J, Clausen, G, and Fanger, P O.
1991.
"Ventilation needs in buildings - establishment of a rational basis for demands from the authorities. Phase 2. Children`s institutions; Ventilationsbehov i bygninger - opstilling af rationelt grundlag for myndighedskrav. Fase 2. Boerneinstitutioner."
Denmark.
@misc{etde_10144699,
title = {Ventilation needs in buildings - establishment of a rational basis for demands from the authorities. Phase 2. Children`s institutions; Ventilationsbehov i bygninger - opstilling af rationelt grundlag for myndighedskrav. Fase 2. Boerneinstitutioner}
author = {Pejtersen, J, Clausen, G, and Fanger, P O}
abstractNote = {Ten kindergartens were investigated in order to determine the pollution load from material sources, ventilations systems and persons. Measurements were based on judgements given by a trained panel of experts, measurements of air change, moisture and air movement as well as of carbon dioxide, carbon monoxide and total volatile organic vapours. With the help of questionnaires the extent and characteristics of irritating symptoms experienced by personnel and the children were examined. Average pollution loads were on average 0.07 olf (2 square meters floor area) from materials, - 0.32 olf (2 square meters floor area) from ventilation systems, and 0.38 olf from persons. Pollution from 244 children aged 3-6 years the extent of pollution was 1.2 olf per child, in relation to the children`s natural niveau of activity. (AB) (12 refs.).}
place = {Denmark}
year = {1991}
month = {Apr}
}
title = {Ventilation needs in buildings - establishment of a rational basis for demands from the authorities. Phase 2. Children`s institutions; Ventilationsbehov i bygninger - opstilling af rationelt grundlag for myndighedskrav. Fase 2. Boerneinstitutioner}
author = {Pejtersen, J, Clausen, G, and Fanger, P O}
abstractNote = {Ten kindergartens were investigated in order to determine the pollution load from material sources, ventilations systems and persons. Measurements were based on judgements given by a trained panel of experts, measurements of air change, moisture and air movement as well as of carbon dioxide, carbon monoxide and total volatile organic vapours. With the help of questionnaires the extent and characteristics of irritating symptoms experienced by personnel and the children were examined. Average pollution loads were on average 0.07 olf (2 square meters floor area) from materials, - 0.32 olf (2 square meters floor area) from ventilation systems, and 0.38 olf from persons. Pollution from 244 children aged 3-6 years the extent of pollution was 1.2 olf per child, in relation to the children`s natural niveau of activity. (AB) (12 refs.).}
place = {Denmark}
year = {1991}
month = {Apr}
}