Abstract

The behaviour of the charging system for the initial commissioning of the Vivitron generator was quite satisfying apart from the excessive parasitic currents at the rollers. That led us to study and test many solutions up to the point that a humidity level higher than thought was discovered as the most probable cause of the problem.
Publication Date:
Mar 01, 1992
Product Type:
Technical Report
Report Number:
CRN-VIV-108
Reference Number:
SCA: 430100; PA: AIX-24:035945; SN: 93000976948
Resource Relation:
Other Information: PBD: Mar 1992
Subject:
43 PARTICLE ACCELERATORS; VIVITRON TANDEM ACCELERATOR; LEAKAGE CURRENT; CHARGE TRANSPORT; ELECTRIC FIELDS; ELECTRICAL INSULATION; ELECTRICAL TESTING; ELECTROSTATICS; HUMIDITY; 430100; DESIGN, DEVELOPMENT, AND OPERATION
OSTI ID:
10144638
Research Organizations:
Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires
Country of Origin:
France
Language:
French
Other Identifying Numbers:
Other: ON: DE93622514; TRN: FR9301983035945
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
FRN
Size:
[3] p.
Announcement Date:
Jul 05, 2005

Citation Formats

Helleboid, J M, Brandt, C, Balzers, P, Delhomme, C, Gaudiot, G, Haberer, A, Koenig, R, Krieg, C, Misslin, F, Neufert, O, Osswald, F, Riehl, F, Schaeffer, E, Schlewer, B, Schuler, J, Sontag, G, Toussaint, J P, and Vogler, H. Charging system functioning of the Vivitron in voltage testings. New developments; Fonctionnement du systeme de charge du Vivitron lors des essais de tension. Nouveaux developpements. France: N. p., 1992. Web.
Helleboid, J M, Brandt, C, Balzers, P, Delhomme, C, Gaudiot, G, Haberer, A, Koenig, R, Krieg, C, Misslin, F, Neufert, O, Osswald, F, Riehl, F, Schaeffer, E, Schlewer, B, Schuler, J, Sontag, G, Toussaint, J P, & Vogler, H. Charging system functioning of the Vivitron in voltage testings. New developments; Fonctionnement du systeme de charge du Vivitron lors des essais de tension. Nouveaux developpements. France.
Helleboid, J M, Brandt, C, Balzers, P, Delhomme, C, Gaudiot, G, Haberer, A, Koenig, R, Krieg, C, Misslin, F, Neufert, O, Osswald, F, Riehl, F, Schaeffer, E, Schlewer, B, Schuler, J, Sontag, G, Toussaint, J P, and Vogler, H. 1992. "Charging system functioning of the Vivitron in voltage testings. New developments; Fonctionnement du systeme de charge du Vivitron lors des essais de tension. Nouveaux developpements." France.
@misc{etde_10144638,
title = {Charging system functioning of the Vivitron in voltage testings. New developments; Fonctionnement du systeme de charge du Vivitron lors des essais de tension. Nouveaux developpements}
author = {Helleboid, J M, Brandt, C, Balzers, P, Delhomme, C, Gaudiot, G, Haberer, A, Koenig, R, Krieg, C, Misslin, F, Neufert, O, Osswald, F, Riehl, F, Schaeffer, E, Schlewer, B, Schuler, J, Sontag, G, Toussaint, J P, and Vogler, H}
abstractNote = {The behaviour of the charging system for the initial commissioning of the Vivitron generator was quite satisfying apart from the excessive parasitic currents at the rollers. That led us to study and test many solutions up to the point that a humidity level higher than thought was discovered as the most probable cause of the problem.}
place = {France}
year = {1992}
month = {Mar}
}