Initial commissioning of the H.V. electrostatic generator for the Vivitron project

Abstract

Early after complete assembly of the Vivitron as an electrostatic generator by the end of October 1990, the initial commissioning began. Voltage tests were done at 7 bars of SF6 from December 1990 to March 1991. An intermediate level of 17.6 MV was reached but with high parasitic currents from the rollers in the dead sections and with flashovers along the column and related damage to the insulating plates. A high level of humidity which has been put in sight later, was the cause of those difficulties. In addition, major problems connected with the gas handling system stopped the tests from the rest of the year up to the end of March 1992 when the generator was made ready for tests after achieving repair and cleaning by the end of January and then implementing some improvements and reassembly. A very encouraging level of 18.9 MV at 4 bars half pressure was reached in April but could not be reproduced up to now due to various problems and damage from sparking.
Publication Date:
Jun 01, 1992
Product Type:
Technical Report
Report Number:
CRN-VIV-105
Reference Number:
SCA: 430100; PA: AIX-24:035942; SN: 93000976945
Resource Relation:
Other Information: PBD: Jun 1992
Subject:
43 PARTICLE ACCELERATORS; VIVITRON TANDEM ACCELERATOR; ELECTRICAL TESTING; BREAKDOWN; CHARGE TRANSPORT; ELECTROSTATICS; HUMIDITY; HVDC SYSTEMS; LEAKAGE CURRENT; 430100; DESIGN, DEVELOPMENT, AND OPERATION
OSTI ID:
10144630
Research Organizations:
Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires
Country of Origin:
France
Language:
English
Other Identifying Numbers:
Other: ON: DE93622511; TRN: FR9301987035942
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
FRN
Size:
[8] p.
Announcement Date:
Jul 05, 2005

Citation Formats

Helleboid, J M, and Vivitron, Groupe. Initial commissioning of the H.V. electrostatic generator for the Vivitron project. France: N. p., 1992. Web.
Helleboid, J M, & Vivitron, Groupe. Initial commissioning of the H.V. electrostatic generator for the Vivitron project. France.
Helleboid, J M, and Vivitron, Groupe. 1992. "Initial commissioning of the H.V. electrostatic generator for the Vivitron project." France.
@misc{etde_10144630,
title = {Initial commissioning of the H.V. electrostatic generator for the Vivitron project}
author = {Helleboid, J M, and Vivitron, Groupe}
abstractNote = {Early after complete assembly of the Vivitron as an electrostatic generator by the end of October 1990, the initial commissioning began. Voltage tests were done at 7 bars of SF6 from December 1990 to March 1991. An intermediate level of 17.6 MV was reached but with high parasitic currents from the rollers in the dead sections and with flashovers along the column and related damage to the insulating plates. A high level of humidity which has been put in sight later, was the cause of those difficulties. In addition, major problems connected with the gas handling system stopped the tests from the rest of the year up to the end of March 1992 when the generator was made ready for tests after achieving repair and cleaning by the end of January and then implementing some improvements and reassembly. A very encouraging level of 18.9 MV at 4 bars half pressure was reached in April but could not be reproduced up to now due to various problems and damage from sparking.}
place = {France}
year = {1992}