Abstract
The aim of the project was to investigate potentials for energy saving by retrofitting an older apartment building comprising 80 flats in Copenhagen, Denmark. The facades of the building were thermally insulated and altered in order to make use of passive solar energy heating and it was attempted to reduce energy consumption to 30% of what it was before so that use of the return water in the local district heating system would be sufficient to heat the building. It was felt to be important that the architecture of the building`s facade was taken into consideration so that the retrofitted building was pleasing to the eye. Between the windows of the southern facade a vertical solar collector was constructed to run down the length of the wall. The ventilation air was used air from, for example, a ventilation heat exchanger. (AB).
Vejsig Pedersen, P;
Balslev-Olesen, O;
[1]
Boyer Rasmussen, K
[2]
- Cenergia ApS (DK)
- Fennet Consult A/S (DK)
Citation Formats
Vejsig Pedersen, P, Balslev-Olesen, O, and Boyer Rasmussen, K.
Pilot project concerning the renovation of an older building in Copenhagen with the combined use of low enery solutions, transparent insulation and low temperature operation of district heating; Forprojekt vedroerende renovering af aeldre ejendom i Koebenhavn med kombineret anvendelse af: lavenergiloesninger, transparent isolering og lavtemperatur fjernvarmedrift.
Denmark: N. p.,
1992.
Web.
Vejsig Pedersen, P, Balslev-Olesen, O, & Boyer Rasmussen, K.
Pilot project concerning the renovation of an older building in Copenhagen with the combined use of low enery solutions, transparent insulation and low temperature operation of district heating; Forprojekt vedroerende renovering af aeldre ejendom i Koebenhavn med kombineret anvendelse af: lavenergiloesninger, transparent isolering og lavtemperatur fjernvarmedrift.
Denmark.
Vejsig Pedersen, P, Balslev-Olesen, O, and Boyer Rasmussen, K.
1992.
"Pilot project concerning the renovation of an older building in Copenhagen with the combined use of low enery solutions, transparent insulation and low temperature operation of district heating; Forprojekt vedroerende renovering af aeldre ejendom i Koebenhavn med kombineret anvendelse af: lavenergiloesninger, transparent isolering og lavtemperatur fjernvarmedrift."
Denmark.
@misc{etde_10144579,
title = {Pilot project concerning the renovation of an older building in Copenhagen with the combined use of low enery solutions, transparent insulation and low temperature operation of district heating; Forprojekt vedroerende renovering af aeldre ejendom i Koebenhavn med kombineret anvendelse af: lavenergiloesninger, transparent isolering og lavtemperatur fjernvarmedrift}
author = {Vejsig Pedersen, P, Balslev-Olesen, O, and Boyer Rasmussen, K}
abstractNote = {The aim of the project was to investigate potentials for energy saving by retrofitting an older apartment building comprising 80 flats in Copenhagen, Denmark. The facades of the building were thermally insulated and altered in order to make use of passive solar energy heating and it was attempted to reduce energy consumption to 30% of what it was before so that use of the return water in the local district heating system would be sufficient to heat the building. It was felt to be important that the architecture of the building`s facade was taken into consideration so that the retrofitted building was pleasing to the eye. Between the windows of the southern facade a vertical solar collector was constructed to run down the length of the wall. The ventilation air was used air from, for example, a ventilation heat exchanger. (AB).}
place = {Denmark}
year = {1992}
month = {Feb}
}
title = {Pilot project concerning the renovation of an older building in Copenhagen with the combined use of low enery solutions, transparent insulation and low temperature operation of district heating; Forprojekt vedroerende renovering af aeldre ejendom i Koebenhavn med kombineret anvendelse af: lavenergiloesninger, transparent isolering og lavtemperatur fjernvarmedrift}
author = {Vejsig Pedersen, P, Balslev-Olesen, O, and Boyer Rasmussen, K}
abstractNote = {The aim of the project was to investigate potentials for energy saving by retrofitting an older apartment building comprising 80 flats in Copenhagen, Denmark. The facades of the building were thermally insulated and altered in order to make use of passive solar energy heating and it was attempted to reduce energy consumption to 30% of what it was before so that use of the return water in the local district heating system would be sufficient to heat the building. It was felt to be important that the architecture of the building`s facade was taken into consideration so that the retrofitted building was pleasing to the eye. Between the windows of the southern facade a vertical solar collector was constructed to run down the length of the wall. The ventilation air was used air from, for example, a ventilation heat exchanger. (AB).}
place = {Denmark}
year = {1992}
month = {Feb}
}