You need JavaScript to view this

Physical investigation in heated and unheated building of the old construction method. Pt. A. Physical bases and general connections of temperature and moisture conditions based on long-time tests; Bauphysikalische Untersuchungen in unbeheizten und beheizten Gebaeuden alter Bauart. T. A. Bauphysikalische Grundlagen und generelle Zusammenhaenge ueber die Temperatur- und Feuchteverhaeltnisse auf Grund von Langzeituntersuchungen

Abstract

The heating of old formerly not heated buildings which often have metres thick walls may due to microclimate changes lead to damage on furnishings. For this reason such buildings are often not heated, but this counteracts contemporary use. As part of a research project the effects of heating have been investigated. It showed that heating of buildings is in principle advantageous for the preservation of the building structure and of furnishings. But heating according to today`s climate standards for rooms which are intended for permanent occupancy is not possible. (BWI). [Deutsch] Die Beheizung von alten, frueher nicht beheizten Gebaeuden mit oft meterdicken Waenden kann durch die Veraenderung des Kleinklimas zu einer besonderen Gefaehrdung der Ausstattung fuehren. Haeufig werden daher derartige Gebaeude nicht beheizt, was jedoch einer heutigen Nutzung entgegenwirkt. Im Rahmen des Forschungsvorhabens wurden die Folgen einer Beheizung untersucht. Es zeigte sich, dass die Beheizung bzw. Temperierung von Gebaeuden fuer die Erhaltung der Bausubstanz und der Einrichtung grundsaetzlich positiv zu bewerten ist. Die Beheizung darf allerdings nicht entsprechend den heutigen Anforderungen an Raeumen erfolgen, die fuer den dauernden Aufenthalt von Menschen bestimmt sind. (BWI).
Authors:
Publication Date:
Dec 31, 1991
Product Type:
Technical Report
Report Number:
IBP-FB-32/1991
Reference Number:
SCA: 320100; PA: DE-92:006088; SN: 92000736248
Resource Relation:
Other Information: PBD: 1991
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; BUILDINGS; RETROFITTING; HEATING SYSTEMS; SPACE HEATING; DAMAGE; RESEARCH PROGRAMS; DESIGN; OPERATION; DIAGRAMS; TEMPERATURE DEPENDENCE; HUMIDITY; DEW POINT; 320100
OSTI ID:
10143963
Research Organizations:
Fraunhofer-Institut fuer Bauphysik, Stuttgart (Germany)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE92516783; TRN: DE9206088
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
DE
Size:
88 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Kuenzel, H, and Holz, D. Physical investigation in heated and unheated building of the old construction method. Pt. A. Physical bases and general connections of temperature and moisture conditions based on long-time tests; Bauphysikalische Untersuchungen in unbeheizten und beheizten Gebaeuden alter Bauart. T. A. Bauphysikalische Grundlagen und generelle Zusammenhaenge ueber die Temperatur- und Feuchteverhaeltnisse auf Grund von Langzeituntersuchungen. Germany: N. p., 1991. Web.
Kuenzel, H, & Holz, D. Physical investigation in heated and unheated building of the old construction method. Pt. A. Physical bases and general connections of temperature and moisture conditions based on long-time tests; Bauphysikalische Untersuchungen in unbeheizten und beheizten Gebaeuden alter Bauart. T. A. Bauphysikalische Grundlagen und generelle Zusammenhaenge ueber die Temperatur- und Feuchteverhaeltnisse auf Grund von Langzeituntersuchungen. Germany.
Kuenzel, H, and Holz, D. 1991. "Physical investigation in heated and unheated building of the old construction method. Pt. A. Physical bases and general connections of temperature and moisture conditions based on long-time tests; Bauphysikalische Untersuchungen in unbeheizten und beheizten Gebaeuden alter Bauart. T. A. Bauphysikalische Grundlagen und generelle Zusammenhaenge ueber die Temperatur- und Feuchteverhaeltnisse auf Grund von Langzeituntersuchungen." Germany.
@misc{etde_10143963,
title = {Physical investigation in heated and unheated building of the old construction method. Pt. A. Physical bases and general connections of temperature and moisture conditions based on long-time tests; Bauphysikalische Untersuchungen in unbeheizten und beheizten Gebaeuden alter Bauart. T. A. Bauphysikalische Grundlagen und generelle Zusammenhaenge ueber die Temperatur- und Feuchteverhaeltnisse auf Grund von Langzeituntersuchungen}
author = {Kuenzel, H, and Holz, D}
abstractNote = {The heating of old formerly not heated buildings which often have metres thick walls may due to microclimate changes lead to damage on furnishings. For this reason such buildings are often not heated, but this counteracts contemporary use. As part of a research project the effects of heating have been investigated. It showed that heating of buildings is in principle advantageous for the preservation of the building structure and of furnishings. But heating according to today`s climate standards for rooms which are intended for permanent occupancy is not possible. (BWI). [Deutsch] Die Beheizung von alten, frueher nicht beheizten Gebaeuden mit oft meterdicken Waenden kann durch die Veraenderung des Kleinklimas zu einer besonderen Gefaehrdung der Ausstattung fuehren. Haeufig werden daher derartige Gebaeude nicht beheizt, was jedoch einer heutigen Nutzung entgegenwirkt. Im Rahmen des Forschungsvorhabens wurden die Folgen einer Beheizung untersucht. Es zeigte sich, dass die Beheizung bzw. Temperierung von Gebaeuden fuer die Erhaltung der Bausubstanz und der Einrichtung grundsaetzlich positiv zu bewerten ist. Die Beheizung darf allerdings nicht entsprechend den heutigen Anforderungen an Raeumen erfolgen, die fuer den dauernden Aufenthalt von Menschen bestimmt sind. (BWI).}
place = {Germany}
year = {1991}
month = {Dec}
}