You need JavaScript to view this

The feasibility of using a Fourier RTOF spectrometer at a low-power research reactor

Abstract

The present situation of Fourier time-of-flight (TOF) spectrometry is discussed using the FSS spectrometer as example. The use of the Fourier reverse TOF spectrometry, as an efficient tool for studying condensed matter, at a 2 MW (WWR-S type) reactor is also assessed. The arrangement of the RTOF spectrometer, which could be successfully used at such type of reactor, is introduced. The suggested arrangement applies a neutron guide tube of 24 m length and allows for effective luminosity 2.4.10{sup 6} at a flight path distance of 3.6 m. The number of neutrons scattered from a sample (5 cm{sup 3} in volume) and incident on the detector system, as estimated for the suggested arrangement, is {proportional_to}1.6.10{sup 3} n/sec. Such high counting rate allows to measure a diffraction spectrum within less than an hour. (orig.) With 12 figs. [Deutsch] Der gegenwaertige Stand der Fourier Neutronen-Flugzeitspektrometrie wird am Beispiel des Spektrometers FSS diskutiert. Insbesondere wird die `reverse time-of-flight` (RTOF)-Methode als effizientes Verfahren zur Untersuchung festkoerper-physikalischer Fragestellungen an Forschungsreaktoren niedriger Leistung (Beispiel: 2 MW Typ WWR-S Reaktor) untersucht. Das Konzept eines RTOF Spektrometers wird vorgestellt: Mit einem Neutronenleiter von 24 m Laenge und 3,6 m Flugweg kann eine effektive Luminositaet von 2,4.10{sup 6} erreicht werden.  More>>
Authors:
Maayouf, R M.A.; [1]  Priesmeyer, H G; [2]  Kudryashev, V A [3] 
  1. Nuclear Research Center, Atomic Energy Authority, Cairo (Egypt). Reactor and Neutron Physics Dept.
  2. Kiel Univ. (Germany). Inst. fuer Reine und Angewandte Kernphysik
  3. Academy of Sciences, Leningrad (USSR). Inst. of Nuclear Physics
Publication Date:
Dec 31, 1991
Product Type:
Technical Report
Report Number:
GKSS-91/E/65
Reference Number:
SCA: 440103; 665100; PA: DEN-92:006235; SN: 92000736397
Resource Relation:
Other Information: PBD: 1991
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY; NEUTRON DIFFRACTOMETERS; TIME-OF-FLIGHT SPECTROMETERS; RESEARCH REACTORS; NEUTRON GUIDES; NEUTRON CHOPPERS; NEUTRON FLUX; LUMINOSITY; COUNTING RATES; TIME DEPENDENCE; 440103; 665100; NUCLEAR SPECTROSCOPIC INSTRUMENTATION; NUCLEAR TECHNIQUES IN CONDENSED MATTER PHYSICS
OSTI ID:
10143366
Research Organizations:
GKSS-Forschungszentrum Geesthacht GmbH, Geesthacht-Tesperhude (Germany)
Country of Origin:
Germany
Language:
English
Other Identifying Numbers:
Other: ON: DE92516930; TRN: DE9206235
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
25 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Maayouf, R M.A., Priesmeyer, H G, and Kudryashev, V A. The feasibility of using a Fourier RTOF spectrometer at a low-power research reactor. Germany: N. p., 1991. Web.
Maayouf, R M.A., Priesmeyer, H G, & Kudryashev, V A. The feasibility of using a Fourier RTOF spectrometer at a low-power research reactor. Germany.
Maayouf, R M.A., Priesmeyer, H G, and Kudryashev, V A. 1991. "The feasibility of using a Fourier RTOF spectrometer at a low-power research reactor." Germany.
@misc{etde_10143366,
title = {The feasibility of using a Fourier RTOF spectrometer at a low-power research reactor}
author = {Maayouf, R M.A., Priesmeyer, H G, and Kudryashev, V A}
abstractNote = {The present situation of Fourier time-of-flight (TOF) spectrometry is discussed using the FSS spectrometer as example. The use of the Fourier reverse TOF spectrometry, as an efficient tool for studying condensed matter, at a 2 MW (WWR-S type) reactor is also assessed. The arrangement of the RTOF spectrometer, which could be successfully used at such type of reactor, is introduced. The suggested arrangement applies a neutron guide tube of 24 m length and allows for effective luminosity 2.4.10{sup 6} at a flight path distance of 3.6 m. The number of neutrons scattered from a sample (5 cm{sup 3} in volume) and incident on the detector system, as estimated for the suggested arrangement, is {proportional_to}1.6.10{sup 3} n/sec. Such high counting rate allows to measure a diffraction spectrum within less than an hour. (orig.) With 12 figs. [Deutsch] Der gegenwaertige Stand der Fourier Neutronen-Flugzeitspektrometrie wird am Beispiel des Spektrometers FSS diskutiert. Insbesondere wird die `reverse time-of-flight` (RTOF)-Methode als effizientes Verfahren zur Untersuchung festkoerper-physikalischer Fragestellungen an Forschungsreaktoren niedriger Leistung (Beispiel: 2 MW Typ WWR-S Reaktor) untersucht. Das Konzept eines RTOF Spektrometers wird vorgestellt: Mit einem Neutronenleiter von 24 m Laenge und 3,6 m Flugweg kann eine effektive Luminositaet von 2,4.10{sup 6} erreicht werden. Die Zahl der gestreuten Neutronen aus einem Volumen von 5 cm{sup 3} wird zu ca. 1,6.10{sup 3} n/sec abgeschaetzt, so dass sich fuer die Aufnahme von Diffraktionsspektren mit dieser Anordnung Messzeiten in der Groessenordnung {proportional_to}1 h ergeben. (orig.) With 12 figs.}
place = {Germany}
year = {1991}
month = {Dec}
}