Abstract
The Burgdorf Engineering School is taking thermal and electrical measurements in the solar systems of a zero energy house on behalf of the Swiss Federal Office of Energy. The size of the solar systems is such that they can cover all the basic requirements of the house residents. In the winter semester 1989/90 the expectations were completely met; some 9.43 MWh of heat energy was gathered by the collectors and the hot water treatment system for the heating used some 3.79 MWh. The heat losses from the three storage devices amounted to 6.09 MWh. The energy of 6.41 MWh which is stored in the large storage devices during the summer was not required. The house has extraordinarily good insulation and is also suitable for the passive use of solar energy. The energy index for the heating system is 67 MJ/m{sup 2}a. The solar systems in the zero energy house do not offer very high efficiency levels which can be explained by their insular operation which not allows the use of excess energy. (author) 11 figs.
Citation Formats
Marti, K.
Zero energy house in Oberburg; Null-Energie-Haus in Oberburg.
Switzerland: N. p.,
1990.
Web.
Marti, K.
Zero energy house in Oberburg; Null-Energie-Haus in Oberburg.
Switzerland.
Marti, K.
1990.
"Zero energy house in Oberburg; Null-Energie-Haus in Oberburg."
Switzerland.
@misc{etde_10143127,
title = {Zero energy house in Oberburg; Null-Energie-Haus in Oberburg}
author = {Marti, K}
abstractNote = {The Burgdorf Engineering School is taking thermal and electrical measurements in the solar systems of a zero energy house on behalf of the Swiss Federal Office of Energy. The size of the solar systems is such that they can cover all the basic requirements of the house residents. In the winter semester 1989/90 the expectations were completely met; some 9.43 MWh of heat energy was gathered by the collectors and the hot water treatment system for the heating used some 3.79 MWh. The heat losses from the three storage devices amounted to 6.09 MWh. The energy of 6.41 MWh which is stored in the large storage devices during the summer was not required. The house has extraordinarily good insulation and is also suitable for the passive use of solar energy. The energy index for the heating system is 67 MJ/m{sup 2}a. The solar systems in the zero energy house do not offer very high efficiency levels which can be explained by their insular operation which not allows the use of excess energy. (author) 11 figs.}
place = {Switzerland}
year = {1990}
month = {Dec}
}
title = {Zero energy house in Oberburg; Null-Energie-Haus in Oberburg}
author = {Marti, K}
abstractNote = {The Burgdorf Engineering School is taking thermal and electrical measurements in the solar systems of a zero energy house on behalf of the Swiss Federal Office of Energy. The size of the solar systems is such that they can cover all the basic requirements of the house residents. In the winter semester 1989/90 the expectations were completely met; some 9.43 MWh of heat energy was gathered by the collectors and the hot water treatment system for the heating used some 3.79 MWh. The heat losses from the three storage devices amounted to 6.09 MWh. The energy of 6.41 MWh which is stored in the large storage devices during the summer was not required. The house has extraordinarily good insulation and is also suitable for the passive use of solar energy. The energy index for the heating system is 67 MJ/m{sup 2}a. The solar systems in the zero energy house do not offer very high efficiency levels which can be explained by their insular operation which not allows the use of excess energy. (author) 11 figs.}
place = {Switzerland}
year = {1990}
month = {Dec}
}