You need JavaScript to view this

On hot water storage in district heating subscriber stations. System measurements

Abstract

The thesis presents laboratory measurements of district heating subscriber stations. Thermodynamic performance characteristics are derived for an experimental subscriber station with a hot water storage tank and an external heat exchanger, but there are also characteristic results for the tank itself. The performance is presented in terms of return temperature, hot water capacity, quality of hot water temperature control and size of heat losses. The laboratory test objects are equipped with accurate measuring devices and a computer program is developed to collect data, to simulate loads of hot water and radiator heat realistically and to control the test rig. A survey is made of several standardized hot water draw-off sequences found in the literature, ending up with adopting the one given in the German DIN-code. Radiator load is simulated by means of a mathematical model and a special load module at the laboratory, to achieve a reproducible and dynamical radiator circuit. Some use is made of simple theoretical models of heat exchangers and storage tanks, when attempting to generalize the conclusions derived from the measurements.
Authors:
Publication Date:
Jan 01, 1992
Product Type:
Thesis/Dissertation
Report Number:
LUTMDN-TMVK-7009-1-76-92
Reference Number:
SCA: 250600; 320603; PA: SWD-92:007053; SN: 92000720077
Resource Relation:
Other Information: TH: Thesis (TeknL).; PBD: Jan 1992
Subject:
25 ENERGY STORAGE; 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; HOT WATER; SENSIBLE HEAT STORAGE; DISTRICT HEATING; STORAGE FACILITIES; STRATIFICATION; BENCH-SCALE EXPERIMENTS; PERFORMANCE TESTING; THERMODYNAMICS; HEAT LOSSES; EXPERIMENTAL DATA; COMPUTERIZED SIMULATION; 250600; 320603; THERMAL; PUBLIC UTILITIES
OSTI ID:
10141804
Research Organizations:
Lund Univ. (Sweden). Dept. of Heat and Power Engineering
Country of Origin:
Sweden
Language:
English
Other Identifying Numbers:
Other: ON: DE92506574; TRN: SE9207053
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
SWD
Size:
71 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Winberg, J. On hot water storage in district heating subscriber stations. System measurements. Sweden: N. p., 1992. Web.
Winberg, J. On hot water storage in district heating subscriber stations. System measurements. Sweden.
Winberg, J. 1992. "On hot water storage in district heating subscriber stations. System measurements." Sweden.
@misc{etde_10141804,
title = {On hot water storage in district heating subscriber stations. System measurements}
author = {Winberg, J}
abstractNote = {The thesis presents laboratory measurements of district heating subscriber stations. Thermodynamic performance characteristics are derived for an experimental subscriber station with a hot water storage tank and an external heat exchanger, but there are also characteristic results for the tank itself. The performance is presented in terms of return temperature, hot water capacity, quality of hot water temperature control and size of heat losses. The laboratory test objects are equipped with accurate measuring devices and a computer program is developed to collect data, to simulate loads of hot water and radiator heat realistically and to control the test rig. A survey is made of several standardized hot water draw-off sequences found in the literature, ending up with adopting the one given in the German DIN-code. Radiator load is simulated by means of a mathematical model and a special load module at the laboratory, to achieve a reproducible and dynamical radiator circuit. Some use is made of simple theoretical models of heat exchangers and storage tanks, when attempting to generalize the conclusions derived from the measurements.}
place = {Sweden}
year = {1992}
month = {Jan}
}