You need JavaScript to view this

Characterization of flue gases from wood fired boilers; Karaktaerisering av roekgaser fraan vedpannor

Abstract

The measurements were made on four small house boilers. Three of them were environmentally approved with improved combustion technology, while the fourth was a traditional boiler. Investigated parameters were: * CO, CO{sub 2}, NO{sub x} and CH{sub x}, * tar and dusts, * 12 volatile organic compounds (VOC), * polycyclic aromatic hydrocarbons, * chlorobenzenes and chlorophenols, * dioxins. Tar content fell below current limit value, 30 mg/MJ, in the approved boilers. The traditional boiler release was 30 times higher than those from the approved ones. Emission of NO{sub x} was 60-76 mg/MJ for the traditional and 100-140 mg/MJ for the approved. Regarding VOC, the traditional boiler release was 2-4 times higher when ackumulator firing, but with direct firing there was no difference. (Numerous figs. and tabs.).
Authors:
Karlsson, M L; Gustavsson, L [1] 
  1. Swedish National Testing and Research Institute, Boraas (Sweden)
Publication Date:
May 01, 1992
Product Type:
Technical Report
Report Number:
NUTEK-FBT-92-6
Reference Number:
SCA: 540120; PA: SWD-92:007068; SN: 92000720092
Resource Relation:
Other Information: PBD: [1992]
Subject:
54 ENVIRONMENTAL SCIENCES; FLUE GAS; CHEMICAL ANALYSIS; WOOD FUELS; TAR; DUSTS; CARBON MONOXIDE; NITROGEN OXIDES; POLYCYCLIC AROMATIC HYDROCARBONS; COMBUSTION PRODUCTS; VOLATILE MATTER; CARBON DIOXIDE; BOILERS; EXPERIMENTAL DATA; EMISSION; 540120; CHEMICALS MONITORING AND TRANSPORT
OSTI ID:
10141796
Research Organizations:
Swedish National Board for Industrial and Technical Development (NUTEK), Stockholm (Sweden)
Country of Origin:
Sweden
Language:
Swedish
Other Identifying Numbers:
Other: ON: DE92506589; CNN: Project NUTEK-276-464; TRN: SE9207068
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
SWD
Size:
73 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Karlsson, M L, and Gustavsson, L. Characterization of flue gases from wood fired boilers; Karaktaerisering av roekgaser fraan vedpannor. Sweden: N. p., 1992. Web.
Karlsson, M L, & Gustavsson, L. Characterization of flue gases from wood fired boilers; Karaktaerisering av roekgaser fraan vedpannor. Sweden.
Karlsson, M L, and Gustavsson, L. 1992. "Characterization of flue gases from wood fired boilers; Karaktaerisering av roekgaser fraan vedpannor." Sweden.
@misc{etde_10141796,
title = {Characterization of flue gases from wood fired boilers; Karaktaerisering av roekgaser fraan vedpannor}
author = {Karlsson, M L, and Gustavsson, L}
abstractNote = {The measurements were made on four small house boilers. Three of them were environmentally approved with improved combustion technology, while the fourth was a traditional boiler. Investigated parameters were: * CO, CO{sub 2}, NO{sub x} and CH{sub x}, * tar and dusts, * 12 volatile organic compounds (VOC), * polycyclic aromatic hydrocarbons, * chlorobenzenes and chlorophenols, * dioxins. Tar content fell below current limit value, 30 mg/MJ, in the approved boilers. The traditional boiler release was 30 times higher than those from the approved ones. Emission of NO{sub x} was 60-76 mg/MJ for the traditional and 100-140 mg/MJ for the approved. Regarding VOC, the traditional boiler release was 2-4 times higher when ackumulator firing, but with direct firing there was no difference. (Numerous figs. and tabs.).}
place = {Sweden}
year = {1992}
month = {May}
}