Abstract
The objective of the subreport concerning technical aspects is to analyse the existing district heating system in Paernu, Estonia, in order to identify technical solutions for renovation. The subreport is a summary of the following technical notes: TN4.01 Heat Production Facilities and Possibilities in Existing Plants. TN4.02 Supply Strategy. TN4.03 Alternative Heat Production Facilities. TN4.04 Hydraulic Network Calculations. TN4.05 Transient Analyses. TN4.06 Renovation of Pipe Network. TN4.07 Selection of Pipe System. TN4.08 Water Quality. TN4.09 Temperature Level. TN4.10 Pressure Level. TN4.11 Location and Build in of Valves. TN4.12 Renovation and Modernization of Pumps. TN4.13 Substations. TN4.14 Consumer Installations. TN4.15 Control and Regulation of Supply System. TN4.16 Computer Systems. TN4.17 Maintenance, and TN4.18 Energy Savings. The texts of the technical notes are included in the publication. It is important that the oil used for fuelling all unites is substituted to a cheap indigenous fuel as peat or wood chips with only peak load based on oil. Information on heat losses - demand and capacity is given in addition to details of needs for technological improvements in the various district heating plants. (AB)
Citation Formats
None.
District heating master plan for Paernu City, Estonia. Technical aspects.
Denmark: N. p.,
1993.
Web.
None.
District heating master plan for Paernu City, Estonia. Technical aspects.
Denmark.
None.
1993.
"District heating master plan for Paernu City, Estonia. Technical aspects."
Denmark.
@misc{etde_10141309,
title = {District heating master plan for Paernu City, Estonia. Technical aspects}
author = {None}
abstractNote = {The objective of the subreport concerning technical aspects is to analyse the existing district heating system in Paernu, Estonia, in order to identify technical solutions for renovation. The subreport is a summary of the following technical notes: TN4.01 Heat Production Facilities and Possibilities in Existing Plants. TN4.02 Supply Strategy. TN4.03 Alternative Heat Production Facilities. TN4.04 Hydraulic Network Calculations. TN4.05 Transient Analyses. TN4.06 Renovation of Pipe Network. TN4.07 Selection of Pipe System. TN4.08 Water Quality. TN4.09 Temperature Level. TN4.10 Pressure Level. TN4.11 Location and Build in of Valves. TN4.12 Renovation and Modernization of Pumps. TN4.13 Substations. TN4.14 Consumer Installations. TN4.15 Control and Regulation of Supply System. TN4.16 Computer Systems. TN4.17 Maintenance, and TN4.18 Energy Savings. The texts of the technical notes are included in the publication. It is important that the oil used for fuelling all unites is substituted to a cheap indigenous fuel as peat or wood chips with only peak load based on oil. Information on heat losses - demand and capacity is given in addition to details of needs for technological improvements in the various district heating plants. (AB)}
place = {Denmark}
year = {1993}
month = {Dec}
}
title = {District heating master plan for Paernu City, Estonia. Technical aspects}
author = {None}
abstractNote = {The objective of the subreport concerning technical aspects is to analyse the existing district heating system in Paernu, Estonia, in order to identify technical solutions for renovation. The subreport is a summary of the following technical notes: TN4.01 Heat Production Facilities and Possibilities in Existing Plants. TN4.02 Supply Strategy. TN4.03 Alternative Heat Production Facilities. TN4.04 Hydraulic Network Calculations. TN4.05 Transient Analyses. TN4.06 Renovation of Pipe Network. TN4.07 Selection of Pipe System. TN4.08 Water Quality. TN4.09 Temperature Level. TN4.10 Pressure Level. TN4.11 Location and Build in of Valves. TN4.12 Renovation and Modernization of Pumps. TN4.13 Substations. TN4.14 Consumer Installations. TN4.15 Control and Regulation of Supply System. TN4.16 Computer Systems. TN4.17 Maintenance, and TN4.18 Energy Savings. The texts of the technical notes are included in the publication. It is important that the oil used for fuelling all unites is substituted to a cheap indigenous fuel as peat or wood chips with only peak load based on oil. Information on heat losses - demand and capacity is given in addition to details of needs for technological improvements in the various district heating plants. (AB)}
place = {Denmark}
year = {1993}
month = {Dec}
}