You need JavaScript to view this

Determination of olf-values for materials used in buildings. Final report for the Pilot project; Bestemmelse af olf-vaerdier for materialer i bygninger; Slutrapport for pilotprojektet

Abstract

The purpose of this pilot project has been to develop a method to quantify the sensory emission rates (olf/m{sup 2}) for materials used in building interiors. In future a compilation of sensory emission rates for the most typical building materials, furniture, carpeting etc. should be desirable, just as the existing data compilation for air conditioning U values. The proposed method consists in measurements in two full-scale chambers of 1030l volume and some small glass vessels, used to establish concentration equilibrium. Materials like rubber, chip board, carpet, have been tested in various ventilation conditions and air quality (in decipols) was estimated by an 11 people strong trained panel. Air age affects considerably human air quality perception. Tests were carried out for 3 different air ages. The recommended air flow rate was 0.9l/s. (EG) (19 refs.)
Publication Date:
Jan 01, 1994
Product Type:
Technical Report
Report Number:
NEI-DK-1463
Reference Number:
SCA: 320107; 560300; PA: DK-94:001131; EDB-94:063673; NTS-94:013490; SN: 94001180414
Resource Relation:
Other Information: DN: EFP-88; PBD: Jan 1994
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; 63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.; AIR QUALITY; TEST FACILITIES; INDOOR AIR POLLUTION; VENTILATION SYSTEMS; AIR POLLUTION ABATEMENT; STATIONARY POLLUTANT SOURCES; DIFFUSION; AIR FLOW; ODOR; 320107; 560300; BUILDING SYSTEMS; CHEMICALS METABOLISM AND TOXICOLOGY
OSTI ID:
10141251
Research Organizations:
Danmarks Tekniske Hoejskole, Lyngby (Denmark). Lab. for Varme- og Klimateknik
Country of Origin:
Denmark
Language:
Danish
Other Identifying Numbers:
Other: ON: DE94756745; CNN: Contract EM-1213/88-3; TRN: DK9401131
Availability:
OSTI; NTIS
Submitting Site:
DK
Size:
36 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Knudsen, H N, Clausen, G, and Fanger, P O. Determination of olf-values for materials used in buildings. Final report for the Pilot project; Bestemmelse af olf-vaerdier for materialer i bygninger; Slutrapport for pilotprojektet. Denmark: N. p., 1994. Web.
Knudsen, H N, Clausen, G, & Fanger, P O. Determination of olf-values for materials used in buildings. Final report for the Pilot project; Bestemmelse af olf-vaerdier for materialer i bygninger; Slutrapport for pilotprojektet. Denmark.
Knudsen, H N, Clausen, G, and Fanger, P O. 1994. "Determination of olf-values for materials used in buildings. Final report for the Pilot project; Bestemmelse af olf-vaerdier for materialer i bygninger; Slutrapport for pilotprojektet." Denmark.
@misc{etde_10141251,
title = {Determination of olf-values for materials used in buildings. Final report for the Pilot project; Bestemmelse af olf-vaerdier for materialer i bygninger; Slutrapport for pilotprojektet}
author = {Knudsen, H N, Clausen, G, and Fanger, P O}
abstractNote = {The purpose of this pilot project has been to develop a method to quantify the sensory emission rates (olf/m{sup 2}) for materials used in building interiors. In future a compilation of sensory emission rates for the most typical building materials, furniture, carpeting etc. should be desirable, just as the existing data compilation for air conditioning U values. The proposed method consists in measurements in two full-scale chambers of 1030l volume and some small glass vessels, used to establish concentration equilibrium. Materials like rubber, chip board, carpet, have been tested in various ventilation conditions and air quality (in decipols) was estimated by an 11 people strong trained panel. Air age affects considerably human air quality perception. Tests were carried out for 3 different air ages. The recommended air flow rate was 0.9l/s. (EG) (19 refs.)}
place = {Denmark}
year = {1994}
month = {Jan}
}