You need JavaScript to view this

Re-check of newly installed solar heating systems; Efterkontrol af nyinstallerede solvarmeanlaeg

Abstract

A detailed re-check of 67 randomly chosen newly installed solar heating installations was carried out in order to gain a general idea of the quality of new installations and data energy consumption, building types etc. Users were interviewed in order to hear their opinions on installation and operation and these were mostly positive, yet the experts considered that some improvements were necessary, especially with regard to optimal yield and a longer service life. It is suggested that a better training of installators is needed in addition to a tighter control of quality assurance on the part of manufacturers and suppliers. (AB).
Authors:
Publication Date:
Dec 01, 1992
Product Type:
Technical Report
Report Number:
NEI-DK-1083
Reference Number:
SCA: 141000; PA: DK-93:001168; SN: 93000967917
Resource Relation:
Other Information: PBD: Dec 1992
Subject:
14 SOLAR ENERGY; SOLAR HEATING SYSTEMS; QUALITY CONTROL; INSPECTION; SOLAR COLLECTORS; INSTALLATION; COST; ERRORS; RELIABILITY; SERVICE LIFE; 141000; SOLAR COLLECTORS AND CONCENTRATORS
OSTI ID:
10140559
Research Organizations:
Dansk Teknologisk Inst., Taastrup (Denmark). Proevestationen for Solenergi
Country of Origin:
Denmark
Language:
Danish
Other Identifying Numbers:
Other: ON: DE93778287; CNN: Contract ENS-51181-92.0007; TRN: DK9301168
Availability:
OSTI; NTIS
Submitting Site:
DK
Size:
[57] p.
Announcement Date:
Jul 05, 2005

Citation Formats

Hansen, B. Re-check of newly installed solar heating systems; Efterkontrol af nyinstallerede solvarmeanlaeg. Denmark: N. p., 1992. Web.
Hansen, B. Re-check of newly installed solar heating systems; Efterkontrol af nyinstallerede solvarmeanlaeg. Denmark.
Hansen, B. 1992. "Re-check of newly installed solar heating systems; Efterkontrol af nyinstallerede solvarmeanlaeg." Denmark.
@misc{etde_10140559,
title = {Re-check of newly installed solar heating systems; Efterkontrol af nyinstallerede solvarmeanlaeg}
author = {Hansen, B}
abstractNote = {A detailed re-check of 67 randomly chosen newly installed solar heating installations was carried out in order to gain a general idea of the quality of new installations and data energy consumption, building types etc. Users were interviewed in order to hear their opinions on installation and operation and these were mostly positive, yet the experts considered that some improvements were necessary, especially with regard to optimal yield and a longer service life. It is suggested that a better training of installators is needed in addition to a tighter control of quality assurance on the part of manufacturers and suppliers. (AB).}
place = {Denmark}
year = {1992}
month = {Dec}
}