Abstract
Local measurements have been performed in three 1.3 MW pulverized coal flames. Two coal types and three burner operating conditions have been investigated. Local in-flame measurements of temperature, gas concentration and residual carbon content have been performed with water cooled probes. By the use of LDA local values of tangential and axial velocities have been measured. The attenuation of a laser beam in different flame types is investigated. The measured data are well suited for the verification of computer models of coal flames and are presented as maps of the furnace room. (au) (11 refs.).
Citation Formats
Jensen, P A, Kirkegaard, M, Bak, J, Rathmann, O, and Clausen, S.
Local measurements in three 1.3 MW pulverized coal flames. Vol. 1. Report for phase 4 of the project: Measurements for the validation of advanced laser based instrumentation and computer models for pulverized coal combustion systems.
Denmark: N. p.,
1992.
Web.
Jensen, P A, Kirkegaard, M, Bak, J, Rathmann, O, & Clausen, S.
Local measurements in three 1.3 MW pulverized coal flames. Vol. 1. Report for phase 4 of the project: Measurements for the validation of advanced laser based instrumentation and computer models for pulverized coal combustion systems.
Denmark.
Jensen, P A, Kirkegaard, M, Bak, J, Rathmann, O, and Clausen, S.
1992.
"Local measurements in three 1.3 MW pulverized coal flames. Vol. 1. Report for phase 4 of the project: Measurements for the validation of advanced laser based instrumentation and computer models for pulverized coal combustion systems."
Denmark.
@misc{etde_10140537,
title = {Local measurements in three 1.3 MW pulverized coal flames. Vol. 1. Report for phase 4 of the project: Measurements for the validation of advanced laser based instrumentation and computer models for pulverized coal combustion systems}
author = {Jensen, P A, Kirkegaard, M, Bak, J, Rathmann, O, and Clausen, S}
abstractNote = {Local measurements have been performed in three 1.3 MW pulverized coal flames. Two coal types and three burner operating conditions have been investigated. Local in-flame measurements of temperature, gas concentration and residual carbon content have been performed with water cooled probes. By the use of LDA local values of tangential and axial velocities have been measured. The attenuation of a laser beam in different flame types is investigated. The measured data are well suited for the verification of computer models of coal flames and are presented as maps of the furnace room. (au) (11 refs.).}
place = {Denmark}
year = {1992}
month = {Nov}
}
title = {Local measurements in three 1.3 MW pulverized coal flames. Vol. 1. Report for phase 4 of the project: Measurements for the validation of advanced laser based instrumentation and computer models for pulverized coal combustion systems}
author = {Jensen, P A, Kirkegaard, M, Bak, J, Rathmann, O, and Clausen, S}
abstractNote = {Local measurements have been performed in three 1.3 MW pulverized coal flames. Two coal types and three burner operating conditions have been investigated. Local in-flame measurements of temperature, gas concentration and residual carbon content have been performed with water cooled probes. By the use of LDA local values of tangential and axial velocities have been measured. The attenuation of a laser beam in different flame types is investigated. The measured data are well suited for the verification of computer models of coal flames and are presented as maps of the furnace room. (au) (11 refs.).}
place = {Denmark}
year = {1992}
month = {Nov}
}