Abstract
Device for measuring nonlinearity of objects with the length of 50 m maximum within the range of {+-}2 mm, based on a new optical element has been created. Sources of possible measurement errors of the device are analyzed. Results of laboratory and production tests are presented. 13 refs.; 5 figs.
Citation Formats
Levashov, Yu I, Mikhal`tsova, I A, Pupkov, Yu A, and Fedotov, M G.
`Laser string` monitor for measuring nonlinearity; Pribor dlya izmereniya nepryamolinejnosti `lazernaya struna`.
USSR: N. p.,
1991.
Web.
Levashov, Yu I, Mikhal`tsova, I A, Pupkov, Yu A, & Fedotov, M G.
`Laser string` monitor for measuring nonlinearity; Pribor dlya izmereniya nepryamolinejnosti `lazernaya struna`.
USSR.
Levashov, Yu I, Mikhal`tsova, I A, Pupkov, Yu A, and Fedotov, M G.
1991.
"`Laser string` monitor for measuring nonlinearity; Pribor dlya izmereniya nepryamolinejnosti `lazernaya struna`."
USSR.
@misc{etde_10140513,
title = {`Laser string` monitor for measuring nonlinearity; Pribor dlya izmereniya nepryamolinejnosti `lazernaya struna`}
author = {Levashov, Yu I, Mikhal`tsova, I A, Pupkov, Yu A, and Fedotov, M G}
abstractNote = {Device for measuring nonlinearity of objects with the length of 50 m maximum within the range of {+-}2 mm, based on a new optical element has been created. Sources of possible measurement errors of the device are analyzed. Results of laboratory and production tests are presented. 13 refs.; 5 figs.}
place = {USSR}
year = {1991}
month = {Dec}
}
title = {`Laser string` monitor for measuring nonlinearity; Pribor dlya izmereniya nepryamolinejnosti `lazernaya struna`}
author = {Levashov, Yu I, Mikhal`tsova, I A, Pupkov, Yu A, and Fedotov, M G}
abstractNote = {Device for measuring nonlinearity of objects with the length of 50 m maximum within the range of {+-}2 mm, based on a new optical element has been created. Sources of possible measurement errors of the device are analyzed. Results of laboratory and production tests are presented. 13 refs.; 5 figs.}
place = {USSR}
year = {1991}
month = {Dec}
}