Abstract
The forward and rear calorimeter of the ZEUS experiment consists of 48 modules. Before their installation into the ZEUS detector they were calibrated at DESY using cosmic ray muons in order to check their performance and to compare the response to cosmic muons to the response, obtained for some modules, to 100 GeV beam muons. The set-up, the test procedure and the analysis of the data are described in this paper. The relative calibration of the different modules, as well as of the different cells within a module can be obtained with cosmic ray muons with an accuracy of about one percent for a measurement time of 3-5 days/module. (orig.)
Behrens, U;
[1]
Cases, G;
[2]
Freidhof, A;
[3]
Fuertjes, A;
[4]
Mitchell, J;
[5]
Molthagen, K;
[6]
Surrow, B;
[4]
Tsurugai, T;
[4]
Yoshida, R
[7]
- Hamburg Univ. (Germany). 1. Inst. fuer Experimentalphysik
- Universidad Autonoma de Madrid (Spain)
- Freiburg Univ. (Germany)
- Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)
- McGill Univ., Montreal, Quebec (Canada)
- Hamburg Univ. (Germany). 2. Inst. fuer Experimentalphysik
- Nationaal Inst. voor Kernfysica en Hoge-Energiefysica (NIKHEF), Amsterdam (Netherlands). Sectie H
Citation Formats
Behrens, U, Cases, G, Freidhof, A, Fuertjes, A, Mitchell, J, Molthagen, K, Surrow, B, Tsurugai, T, and Yoshida, R.
Calibration of the forward and rear ZEUS calorimeter using cosmic ray muons.
Germany: N. p.,
1993.
Web.
Behrens, U, Cases, G, Freidhof, A, Fuertjes, A, Mitchell, J, Molthagen, K, Surrow, B, Tsurugai, T, & Yoshida, R.
Calibration of the forward and rear ZEUS calorimeter using cosmic ray muons.
Germany.
Behrens, U, Cases, G, Freidhof, A, Fuertjes, A, Mitchell, J, Molthagen, K, Surrow, B, Tsurugai, T, and Yoshida, R.
1993.
"Calibration of the forward and rear ZEUS calorimeter using cosmic ray muons."
Germany.
@misc{etde_10139934,
title = {Calibration of the forward and rear ZEUS calorimeter using cosmic ray muons}
author = {Behrens, U, Cases, G, Freidhof, A, Fuertjes, A, Mitchell, J, Molthagen, K, Surrow, B, Tsurugai, T, and Yoshida, R}
abstractNote = {The forward and rear calorimeter of the ZEUS experiment consists of 48 modules. Before their installation into the ZEUS detector they were calibrated at DESY using cosmic ray muons in order to check their performance and to compare the response to cosmic muons to the response, obtained for some modules, to 100 GeV beam muons. The set-up, the test procedure and the analysis of the data are described in this paper. The relative calibration of the different modules, as well as of the different cells within a module can be obtained with cosmic ray muons with an accuracy of about one percent for a measurement time of 3-5 days/module. (orig.)}
place = {Germany}
year = {1993}
month = {Aug}
}
title = {Calibration of the forward and rear ZEUS calorimeter using cosmic ray muons}
author = {Behrens, U, Cases, G, Freidhof, A, Fuertjes, A, Mitchell, J, Molthagen, K, Surrow, B, Tsurugai, T, and Yoshida, R}
abstractNote = {The forward and rear calorimeter of the ZEUS experiment consists of 48 modules. Before their installation into the ZEUS detector they were calibrated at DESY using cosmic ray muons in order to check their performance and to compare the response to cosmic muons to the response, obtained for some modules, to 100 GeV beam muons. The set-up, the test procedure and the analysis of the data are described in this paper. The relative calibration of the different modules, as well as of the different cells within a module can be obtained with cosmic ray muons with an accuracy of about one percent for a measurement time of 3-5 days/module. (orig.)}
place = {Germany}
year = {1993}
month = {Aug}
}