Abstract
This article reports on studies aimed to characterise the properties of plastic scintillating fibres to be used in head-on, 1:1 Pb-SCIFI calorimetric modules. The effect of glue on the attenuation of the light transported by cladding close to the photomultiplier tube is studied and found to effectivaly decrease the contribution of cladding light. Pb-SCIFI modules have been assembled and tested on a 20-80 Mev tagged photon beam. Good linearity and energy resolution better than 6%/{radical}E[GeV] were achieved, therefore showing that this technique is suitable for experimental at {phi}-factories.
Bianco, S;
Casaccia, R;
Daniello, L;
Fabbri, F L;
Giardoni, M;
Zallo, A;
Lindozzi, M;
Passamonti, L;
Russo, V;
Sarwar, S;
Votano, L;
[1]
Mertzog, D;
Hughes, S;
Reimer, P;
Tayloe, R
[2]
- Istituto Nazionale di Fisica Nucleare, Frascati (Italy). Lab. Nazionale di Frascati
- Illinois Univ., Urbana, IL (United States)
Citation Formats
Bianco, S, Casaccia, R, Daniello, L, Fabbri, F L, Giardoni, M, Zallo, A, Lindozzi, M, Passamonti, L, Russo, V, Sarwar, S, Votano, L, Mertzog, D, Hughes, S, Reimer, P, and Tayloe, R.
High-resolution, low-energy e.m. Pb-SCIFI calorimetry. An investigation on fibres and tests on photon beam with low-energy photons.
Italy: N. p.,
1991.
Web.
Bianco, S, Casaccia, R, Daniello, L, Fabbri, F L, Giardoni, M, Zallo, A, Lindozzi, M, Passamonti, L, Russo, V, Sarwar, S, Votano, L, Mertzog, D, Hughes, S, Reimer, P, & Tayloe, R.
High-resolution, low-energy e.m. Pb-SCIFI calorimetry. An investigation on fibres and tests on photon beam with low-energy photons.
Italy.
Bianco, S, Casaccia, R, Daniello, L, Fabbri, F L, Giardoni, M, Zallo, A, Lindozzi, M, Passamonti, L, Russo, V, Sarwar, S, Votano, L, Mertzog, D, Hughes, S, Reimer, P, and Tayloe, R.
1991.
"High-resolution, low-energy e.m. Pb-SCIFI calorimetry. An investigation on fibres and tests on photon beam with low-energy photons."
Italy.
@misc{etde_10139839,
title = {High-resolution, low-energy e.m. Pb-SCIFI calorimetry. An investigation on fibres and tests on photon beam with low-energy photons}
author = {Bianco, S, Casaccia, R, Daniello, L, Fabbri, F L, Giardoni, M, Zallo, A, Lindozzi, M, Passamonti, L, Russo, V, Sarwar, S, Votano, L, Mertzog, D, Hughes, S, Reimer, P, and Tayloe, R}
abstractNote = {This article reports on studies aimed to characterise the properties of plastic scintillating fibres to be used in head-on, 1:1 Pb-SCIFI calorimetric modules. The effect of glue on the attenuation of the light transported by cladding close to the photomultiplier tube is studied and found to effectivaly decrease the contribution of cladding light. Pb-SCIFI modules have been assembled and tested on a 20-80 Mev tagged photon beam. Good linearity and energy resolution better than 6%/{radical}E[GeV] were achieved, therefore showing that this technique is suitable for experimental at {phi}-factories.}
place = {Italy}
year = {1991}
month = {Dec}
}
title = {High-resolution, low-energy e.m. Pb-SCIFI calorimetry. An investigation on fibres and tests on photon beam with low-energy photons}
author = {Bianco, S, Casaccia, R, Daniello, L, Fabbri, F L, Giardoni, M, Zallo, A, Lindozzi, M, Passamonti, L, Russo, V, Sarwar, S, Votano, L, Mertzog, D, Hughes, S, Reimer, P, and Tayloe, R}
abstractNote = {This article reports on studies aimed to characterise the properties of plastic scintillating fibres to be used in head-on, 1:1 Pb-SCIFI calorimetric modules. The effect of glue on the attenuation of the light transported by cladding close to the photomultiplier tube is studied and found to effectivaly decrease the contribution of cladding light. Pb-SCIFI modules have been assembled and tested on a 20-80 Mev tagged photon beam. Good linearity and energy resolution better than 6%/{radical}E[GeV] were achieved, therefore showing that this technique is suitable for experimental at {phi}-factories.}
place = {Italy}
year = {1991}
month = {Dec}
}