Abstract
The method is described and the results of measuring of electron ring density distribution are presented. A TV-camera on the basis of a CCD matrix is used as a sensing element. The camera is connected through the interface unit in CAMAC standard with the SM-4 computer. The time exposition of radiaiton is realized by using an electro-optic sutter in the time interval from 0.01 to 1 ms at an operation voltage of 1 kV. 5 refs.
Citation Formats
Damish, Yu, Drozdov, V A, Tyutyunnikov, S I, and Shalyapin, V N.
Application of CCD-camera for size measuring of electron ring by means of synchrotron radiation; Primenie PZS-telekamery dlya izmereniya razmerov ehlektronnykh kolets po sinkhrotronnomu izlucheniyu.
USSR: N. p.,
1990.
Web.
Damish, Yu, Drozdov, V A, Tyutyunnikov, S I, & Shalyapin, V N.
Application of CCD-camera for size measuring of electron ring by means of synchrotron radiation; Primenie PZS-telekamery dlya izmereniya razmerov ehlektronnykh kolets po sinkhrotronnomu izlucheniyu.
USSR.
Damish, Yu, Drozdov, V A, Tyutyunnikov, S I, and Shalyapin, V N.
1990.
"Application of CCD-camera for size measuring of electron ring by means of synchrotron radiation; Primenie PZS-telekamery dlya izmereniya razmerov ehlektronnykh kolets po sinkhrotronnomu izlucheniyu."
USSR.
@misc{etde_10139757,
title = {Application of CCD-camera for size measuring of electron ring by means of synchrotron radiation; Primenie PZS-telekamery dlya izmereniya razmerov ehlektronnykh kolets po sinkhrotronnomu izlucheniyu}
author = {Damish, Yu, Drozdov, V A, Tyutyunnikov, S I, and Shalyapin, V N}
abstractNote = {The method is described and the results of measuring of electron ring density distribution are presented. A TV-camera on the basis of a CCD matrix is used as a sensing element. The camera is connected through the interface unit in CAMAC standard with the SM-4 computer. The time exposition of radiaiton is realized by using an electro-optic sutter in the time interval from 0.01 to 1 ms at an operation voltage of 1 kV. 5 refs.}
place = {USSR}
year = {1990}
month = {Dec}
}
title = {Application of CCD-camera for size measuring of electron ring by means of synchrotron radiation; Primenie PZS-telekamery dlya izmereniya razmerov ehlektronnykh kolets po sinkhrotronnomu izlucheniyu}
author = {Damish, Yu, Drozdov, V A, Tyutyunnikov, S I, and Shalyapin, V N}
abstractNote = {The method is described and the results of measuring of electron ring density distribution are presented. A TV-camera on the basis of a CCD matrix is used as a sensing element. The camera is connected through the interface unit in CAMAC standard with the SM-4 computer. The time exposition of radiaiton is realized by using an electro-optic sutter in the time interval from 0.01 to 1 ms at an operation voltage of 1 kV. 5 refs.}
place = {USSR}
year = {1990}
month = {Dec}
}