Abstract
UP2 800 plant, now on building at ``La Hague``, is equipped with an accountability tank of 20 m{sup 3} volume. That tank is used to feed the facility with solution transfers; these transfers are triggered by siphons. This paper describes calibration measures realized with that tank for setting up the curve of volume V versus the level H and for finding the volumes left after clipping of siphons. It presents also the results for the level differences between the end points of bubbling tubes. Results are given, with the corresponding accuracy, in the case of measures with water as solution. Further tests will be made with uranyl nitrate. (authors). 3 refs.
Cauchetier, Ph;
Roche, C;
[1]
Dufour, J L;
[2]
Neuilly, M;
Fournier, P;
Evain, D;
[3]
Blandeau, L;
Janin, V
[4]
- CEA Centre d`Etudes de la Vallee du Rhone, 30 - Marcoule (France). Dept. des Procedes de Retraitement
- CEA Centre d`Etudes de Fontenay-aux-Roses, 92 (France). Inst. de Protection et de Surete Nucleaire
- Compagnie Generale des Matieres Nucleaires (COGEMA), 78 - Velizy-Villacoublay (France)
- Societe Generale pour les Techniques Nouvelles (SGN), 78 - Saint-Quentin-en-Yvelines (France)
Citation Formats
Cauchetier, Ph, Roche, C, Dufour, J L, Neuilly, M, Fournier, P, Evain, D, Blandeau, L, and Janin, V.
Calibration of UP2 800 accountancy tank; Etalonnage de la cuve de comptabilite de UP2 800 (La Hague).
France: N. p.,
1993.
Web.
Cauchetier, Ph, Roche, C, Dufour, J L, Neuilly, M, Fournier, P, Evain, D, Blandeau, L, & Janin, V.
Calibration of UP2 800 accountancy tank; Etalonnage de la cuve de comptabilite de UP2 800 (La Hague).
France.
Cauchetier, Ph, Roche, C, Dufour, J L, Neuilly, M, Fournier, P, Evain, D, Blandeau, L, and Janin, V.
1993.
"Calibration of UP2 800 accountancy tank; Etalonnage de la cuve de comptabilite de UP2 800 (La Hague)."
France.
@misc{etde_10139698,
title = {Calibration of UP2 800 accountancy tank; Etalonnage de la cuve de comptabilite de UP2 800 (La Hague)}
author = {Cauchetier, Ph, Roche, C, Dufour, J L, Neuilly, M, Fournier, P, Evain, D, Blandeau, L, and Janin, V}
abstractNote = {UP2 800 plant, now on building at ``La Hague``, is equipped with an accountability tank of 20 m{sup 3} volume. That tank is used to feed the facility with solution transfers; these transfers are triggered by siphons. This paper describes calibration measures realized with that tank for setting up the curve of volume V versus the level H and for finding the volumes left after clipping of siphons. It presents also the results for the level differences between the end points of bubbling tubes. Results are given, with the corresponding accuracy, in the case of measures with water as solution. Further tests will be made with uranyl nitrate. (authors). 3 refs.}
place = {France}
year = {1993}
month = {Dec}
}
title = {Calibration of UP2 800 accountancy tank; Etalonnage de la cuve de comptabilite de UP2 800 (La Hague)}
author = {Cauchetier, Ph, Roche, C, Dufour, J L, Neuilly, M, Fournier, P, Evain, D, Blandeau, L, and Janin, V}
abstractNote = {UP2 800 plant, now on building at ``La Hague``, is equipped with an accountability tank of 20 m{sup 3} volume. That tank is used to feed the facility with solution transfers; these transfers are triggered by siphons. This paper describes calibration measures realized with that tank for setting up the curve of volume V versus the level H and for finding the volumes left after clipping of siphons. It presents also the results for the level differences between the end points of bubbling tubes. Results are given, with the corresponding accuracy, in the case of measures with water as solution. Further tests will be made with uranyl nitrate. (authors). 3 refs.}
place = {France}
year = {1993}
month = {Dec}
}