Abstract
CONTAIN code calculations and hand calculations have been performed for the containment thermal-hydraulic and aerosol behaviour of the CT-6 experiment in the Falcon facility. Both single-cell and 9-cell CONTAIN calculations were performed. The 9-cell calculations gave much better agreement with the measured data, indicating that there were significant inhomogeneities in the containment atmosphere during the test. (author).
Smith, P N;
Roberts, G J
[1]
- AEA Thermal Reactor Services, Winfrith (United Kingdom). Reactor Safety Studies Dept.
Citation Formats
Smith, P N, and Roberts, G J.
Analysis of the Falcon CT-6 experiment.
United Kingdom: N. p.,
1991.
Web.
Smith, P N, & Roberts, G J.
Analysis of the Falcon CT-6 experiment.
United Kingdom.
Smith, P N, and Roberts, G J.
1991.
"Analysis of the Falcon CT-6 experiment."
United Kingdom.
@misc{etde_10138434,
title = {Analysis of the Falcon CT-6 experiment}
author = {Smith, P N, and Roberts, G J}
abstractNote = {CONTAIN code calculations and hand calculations have been performed for the containment thermal-hydraulic and aerosol behaviour of the CT-6 experiment in the Falcon facility. Both single-cell and 9-cell CONTAIN calculations were performed. The 9-cell calculations gave much better agreement with the measured data, indicating that there were significant inhomogeneities in the containment atmosphere during the test. (author).}
place = {United Kingdom}
year = {1991}
month = {Mar}
}
title = {Analysis of the Falcon CT-6 experiment}
author = {Smith, P N, and Roberts, G J}
abstractNote = {CONTAIN code calculations and hand calculations have been performed for the containment thermal-hydraulic and aerosol behaviour of the CT-6 experiment in the Falcon facility. Both single-cell and 9-cell CONTAIN calculations were performed. The 9-cell calculations gave much better agreement with the measured data, indicating that there were significant inhomogeneities in the containment atmosphere during the test. (author).}
place = {United Kingdom}
year = {1991}
month = {Mar}
}