Abstract

Based upon the results of phase 1 the concept of an integrated Hard Coal Gasification Combined Cycle Power Plant was developed in cooperation with the companies Linde and Krupp Koppers and the basic design of a 170 MW-prototype power plant was performed for a site of Stadtwerke Duisburg. SIEMENS has designed the GUD power plant and the auxiliary systems as well as developed the optimal integration of the subsystems coal gas generation, air separation and GUD power plant; therefore a high plant efficiency is reached. As a result of this work, the plant concept is characterized by the following main features: -entrained flow gasification with the PRENFLO gasifier -crude gas heat recovery in two stages for HP- and IP-steam generation -GUD power plant with two HT-gasturbines V 64 and triple-pressure steam process with reheat. The results of the study show the advantages of this power plant type, especially high plant efficiency and low pollution of the environment. The results are to be employed as basis for the decision of the Stadtwerke Duisburg to build such a plant. (orig.) With 13 figs., 10 refs., 1 tab. [Deutsch] Auf der Basis der Ergebnisse der Projektdefinitionsphase wurden in Zusammenarbeit mit den Firmen Krupp  More>>
Publication Date:
Oct 01, 1991
Product Type:
Conference
Report Number:
SIEMENS-KWU-E-33/91/002; CONF-9105247-1
Reference Number:
SCA: 200102; 010404; PA: DE-93:003210; SN: 93000960129
Resource Relation:
Conference: VGB conference coal gasification with information show,VGB-Konferenz Kohlevergasung mit Informationsschau,Dortmund (Germany),16-17 May 1991; Other Information: PBD: Oct 1991
Subject:
20 FOSSIL-FUELED POWER PLANTS; 01 COAL, LIGNITE, AND PEAT; COMBINED-CYCLE POWER PLANTS; COAL GASIFICATION; HOT GAS CLEANUP; OPERATION; PILOT PLANTS; GAS TURBINES; TEMPERATURE RANGE 0400-1000 K; EFFICIENCY; AIR POLLUTION CONTROL; PRENFLO PROCESS; PROCESS CONTROL; ON-LINE CONTROL SYSTEMS; EMISSION; FLOWSHEETS; INVESTMENT; 200102; 010404; POWER CYCLES; GASIFICATION
OSTI ID:
10137988
Research Organizations:
Siemens AG Unternehmensbereich KWU, Erlangen (Germany). Bereich Energieerzeugung; Bundesministerium fuer Forschung und Technologie, Bonn (Germany)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE93774751; CNN: Contract BMFT 03E-6232-B; TRN: DE9303210
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
DE
Size:
34 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Baumgaertel, G, Mueller, R, and Schiffers, U. Integrated coal gasification combined cycle power plant, design of the prototype power plant (phase 2 A). Final report; Kombiniertes Gas- und Dampfturbinenkraftwerk mit Kohlevergasung, Planung des Prototypkraftwerks (Phase 2 A). Schlussbericht. Germany: N. p., 1991. Web.
Baumgaertel, G, Mueller, R, & Schiffers, U. Integrated coal gasification combined cycle power plant, design of the prototype power plant (phase 2 A). Final report; Kombiniertes Gas- und Dampfturbinenkraftwerk mit Kohlevergasung, Planung des Prototypkraftwerks (Phase 2 A). Schlussbericht. Germany.
Baumgaertel, G, Mueller, R, and Schiffers, U. 1991. "Integrated coal gasification combined cycle power plant, design of the prototype power plant (phase 2 A). Final report; Kombiniertes Gas- und Dampfturbinenkraftwerk mit Kohlevergasung, Planung des Prototypkraftwerks (Phase 2 A). Schlussbericht." Germany.
@misc{etde_10137988,
title = {Integrated coal gasification combined cycle power plant, design of the prototype power plant (phase 2 A). Final report; Kombiniertes Gas- und Dampfturbinenkraftwerk mit Kohlevergasung, Planung des Prototypkraftwerks (Phase 2 A). Schlussbericht}
author = {Baumgaertel, G, Mueller, R, and Schiffers, U}
abstractNote = {Based upon the results of phase 1 the concept of an integrated Hard Coal Gasification Combined Cycle Power Plant was developed in cooperation with the companies Linde and Krupp Koppers and the basic design of a 170 MW-prototype power plant was performed for a site of Stadtwerke Duisburg. SIEMENS has designed the GUD power plant and the auxiliary systems as well as developed the optimal integration of the subsystems coal gas generation, air separation and GUD power plant; therefore a high plant efficiency is reached. As a result of this work, the plant concept is characterized by the following main features: -entrained flow gasification with the PRENFLO gasifier -crude gas heat recovery in two stages for HP- and IP-steam generation -GUD power plant with two HT-gasturbines V 64 and triple-pressure steam process with reheat. The results of the study show the advantages of this power plant type, especially high plant efficiency and low pollution of the environment. The results are to be employed as basis for the decision of the Stadtwerke Duisburg to build such a plant. (orig.) With 13 figs., 10 refs., 1 tab. [Deutsch] Auf der Basis der Ergebnisse der Projektdefinitionsphase wurden in Zusammenarbeit mit den Firmen Krupp Koppers und Linde das Konzept eines GUD-Kraftwerkes mit integrierter Steinkohlevergasung entwickelt und die grundlegende Planung fuer ein 170-MW-Prototypkraftwerk an einem Standort der Stadtwerke Duisburg durchgefuehrt. SIEMENS hat im Rahmen dieser Studie die Auslegung des GUD-Kraftwerkteiles einschliesslich der Nebenanlagen vorgenommen sowie die optimale Verschaltung der Teilanlagen Kohlegaserzeugung, Luftzerlegungsanlage und GUD-Kraftwerk entwickelt, wobei ein hoher Anlagenwirkungsgrad erreicht werden kann. Als Ergebnis dieser Arbeiten wurde ein Anlagenkonzept entwickelt, das durch folgende Hauptmerkmale gekennzeichnet ist: -Flugstromvergasung im PRENFLO-Vergaser -Zweistufige Rohgasabhitzenutzung zur HD- und MD-Dampferzeugung -GUD-Kraftwerk mit 2 HT-Gasturbinen V64 und Dreidruckdampfprozess mit Zwischenueberhitzung. Die Ergebnisse der Studie zeigen die Vorteile dieses Kraftwerktypes, insbes. hoher Wirkungsgrad und niedrige Umweltbelastung. Die Ergebnisse dienen als Basisunterlagen fuer einen Bauentscheid der Stadtwerke Duisburg. (orig.) With 13 figs., 10 refs., 1 tab.}
place = {Germany}
year = {1991}
month = {Oct}
}