Abstract
The thermoluminescence (TL) method based on TOLEDO apparatus has been carried out, firstly in Vietnam, for identification of some irradiated dry food: paprika, pepper, curry and green beans. The TL effect of irradiation with dose 0.8 Mrad is greater than the effect of unirradiated samples at least by one order. The TOLEDO was proved to be able to determine TL intensity as function of absorbed dose and post-irradiation storage time. The measurement procedure is rapid and simple, that expect to be used as a standard control method of irradiated food. (author). 6 refs, 2 figs, 1 tab.
Thuan, Vo Van;
Vinh, Pham Quang;
[1]
Luong, Dang Thanh;
Dien, Pham Quang
[2]
- Irrad. Cent. (Viet Nam)
- Div. Rad. Protec. Nucl. Safety (Viet Nam)
Citation Formats
Thuan, Vo Van, Vinh, Pham Quang, Luong, Dang Thanh, and Dien, Pham Quang.
Identification of irradiated foods using the thermoluminescence apparatus TOLEDO - Preliminary study.
Viet Nam: N. p.,
1990.
Web.
Thuan, Vo Van, Vinh, Pham Quang, Luong, Dang Thanh, & Dien, Pham Quang.
Identification of irradiated foods using the thermoluminescence apparatus TOLEDO - Preliminary study.
Viet Nam.
Thuan, Vo Van, Vinh, Pham Quang, Luong, Dang Thanh, and Dien, Pham Quang.
1990.
"Identification of irradiated foods using the thermoluminescence apparatus TOLEDO - Preliminary study."
Viet Nam.
@misc{etde_10136053,
title = {Identification of irradiated foods using the thermoluminescence apparatus TOLEDO - Preliminary study}
author = {Thuan, Vo Van, Vinh, Pham Quang, Luong, Dang Thanh, and Dien, Pham Quang}
abstractNote = {The thermoluminescence (TL) method based on TOLEDO apparatus has been carried out, firstly in Vietnam, for identification of some irradiated dry food: paprika, pepper, curry and green beans. The TL effect of irradiation with dose 0.8 Mrad is greater than the effect of unirradiated samples at least by one order. The TOLEDO was proved to be able to determine TL intensity as function of absorbed dose and post-irradiation storage time. The measurement procedure is rapid and simple, that expect to be used as a standard control method of irradiated food. (author). 6 refs, 2 figs, 1 tab.}
place = {Viet Nam}
year = {1990}
month = {Dec}
}
title = {Identification of irradiated foods using the thermoluminescence apparatus TOLEDO - Preliminary study}
author = {Thuan, Vo Van, Vinh, Pham Quang, Luong, Dang Thanh, and Dien, Pham Quang}
abstractNote = {The thermoluminescence (TL) method based on TOLEDO apparatus has been carried out, firstly in Vietnam, for identification of some irradiated dry food: paprika, pepper, curry and green beans. The TL effect of irradiation with dose 0.8 Mrad is greater than the effect of unirradiated samples at least by one order. The TOLEDO was proved to be able to determine TL intensity as function of absorbed dose and post-irradiation storage time. The measurement procedure is rapid and simple, that expect to be used as a standard control method of irradiated food. (author). 6 refs, 2 figs, 1 tab.}
place = {Viet Nam}
year = {1990}
month = {Dec}
}