You need JavaScript to view this

Results of lasing linewidth narrowing on VEPP-3 storage ring optical klystron

Abstract

In order to decrease the linewidth optical cavity on VEPP-3 storage ring optical klystron was up-dated. A glass plate with parallel planes as natural interferometer was used. With the 1.2 mm thick glass plate installed inside the optical cavity lasing with a very narrow linewidth have been reached. The minimum relative lasing linewidth, 2.7x10{sup -6} ({lambda}=6250A, {Delta}{lambda}=0.017A) was 30 time narrower than the minimum one without the plate ({Delta}{lambda}=0.6A). The average power was the same in both cases. 6 refs.; 6 figs.
Authors:
Couprie, M -E; Gavrilov, N G; Kulipanov, G N [1] 
  1. and others
Publication Date:
Dec 31, 1991
Product Type:
Technical Report
Report Number:
IYaF-91-4
Reference Number:
SCA: 430400; PA: AIX-23:031709; SN: 92000710072
Resource Relation:
Other Information: PBD: 1991
Subject:
43 PARTICLE ACCELERATORS; FREE ELECTRON LASERS; CAVITY RESONATORS; VEPP-3; GLASS; INTERFEROMETERS; LASER RADIATION; LINE WIDTHS; MODIFICATIONS; MODULATION; PLATES; ULTRAVIOLET RADIATION; 430400; STORAGE RINGS
OSTI ID:
10135808
Research Organizations:
AN SSSR, Novosibirsk (Russian Federation). Inst. Yadernoj Fiziki
Country of Origin:
USSR
Language:
English
Other Identifying Numbers:
Other: ON: DE92624179; TRN: SU9202078031709
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
17 p.
Announcement Date:
Jul 05, 2005

Citation Formats

Couprie, M -E, Gavrilov, N G, and Kulipanov, G N. Results of lasing linewidth narrowing on VEPP-3 storage ring optical klystron. USSR: N. p., 1991. Web.
Couprie, M -E, Gavrilov, N G, & Kulipanov, G N. Results of lasing linewidth narrowing on VEPP-3 storage ring optical klystron. USSR.
Couprie, M -E, Gavrilov, N G, and Kulipanov, G N. 1991. "Results of lasing linewidth narrowing on VEPP-3 storage ring optical klystron." USSR.
@misc{etde_10135808,
title = {Results of lasing linewidth narrowing on VEPP-3 storage ring optical klystron}
author = {Couprie, M -E, Gavrilov, N G, and Kulipanov, G N}
abstractNote = {In order to decrease the linewidth optical cavity on VEPP-3 storage ring optical klystron was up-dated. A glass plate with parallel planes as natural interferometer was used. With the 1.2 mm thick glass plate installed inside the optical cavity lasing with a very narrow linewidth have been reached. The minimum relative lasing linewidth, 2.7x10{sup -6} ({lambda}=6250A, {Delta}{lambda}=0.017A) was 30 time narrower than the minimum one without the plate ({Delta}{lambda}=0.6A). The average power was the same in both cases. 6 refs.; 6 figs.}
place = {USSR}
year = {1991}
month = {Dec}
}