Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV

Abstract

In the piercing horizontal channel of the Dalat nuclear research reactor a 98cm long silicon filter has been installed for producing quasi-monoenergetic neutrons of 55 keV and 144 keV. The flux intensities of the neutron beams are 4x10{sup 6} n/cm{sup 2}.s (55 keV) and 1.2x10{sup 7} n/cm{sup 2}.s (144 keV). Filtered neutron beams are being utilized for the measurements of the resonance-averaged nuclear parameters. In the first experiments aiming partly at testing the adequacy of the experimental conditions total neutron cross-sections have been measured by transmission technique for U-238 and C-12 target nuclei. The data for U-238 obtained with the accuracy of about 1% were compared with the evaluated ENDF/B-IV data and the results of recent experimental works. (author). 4 figs, 6 refs, 2 tabs.
Publication Date:
Apr 01, 1993
Product Type:
Miscellaneous
Report Number:
INIS-mf-13498
Reference Number:
SCA: 663430; 663520; 663590; PA: AIX-24:034295; SN: 93000963810
Resource Relation:
Other Information: PBD: [1993]
Subject:
73 NUCLEAR PHYSICS AND RADIATION PHYSICS; CARBON 12 TARGET; NEUTRON REACTIONS; URANIUM 238 TARGET; EXPERIMENTAL DATA; INTERMEDIATE NEUTRONS; NEUTRON FLUX; TOTAL CROSS SECTIONS; TRIGA-2-DALAT REACTOR; 663430; 663520; 663590; NUCLEON-INDUCED REACTIONS AND SCATTERING; A = 6-19; A = 220 AND ABOVE
OSTI ID:
10135372
Research Organizations:
Nuclear Research Inst., Da Lat (Viet Nam)
Country of Origin:
Viet Nam
Language:
English
Other Identifying Numbers:
Other: ON: DE93621481; TRN: VN9300008034295
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
[12] p.
Announcement Date:
Jul 05, 2005

Citation Formats

Hien, Pham Zuy, Tan, Vuong Huu, and Xuan, Nguyen Phuoc. Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV. Viet Nam: N. p., 1993. Web.
Hien, Pham Zuy, Tan, Vuong Huu, & Xuan, Nguyen Phuoc. Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV. Viet Nam.
Hien, Pham Zuy, Tan, Vuong Huu, and Xuan, Nguyen Phuoc. 1993. "Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV." Viet Nam.
@misc{etde_10135372,
title = {Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV}
author = {Hien, Pham Zuy, Tan, Vuong Huu, and Xuan, Nguyen Phuoc}
abstractNote = {In the piercing horizontal channel of the Dalat nuclear research reactor a 98cm long silicon filter has been installed for producing quasi-monoenergetic neutrons of 55 keV and 144 keV. The flux intensities of the neutron beams are 4x10{sup 6} n/cm{sup 2}.s (55 keV) and 1.2x10{sup 7} n/cm{sup 2}.s (144 keV). Filtered neutron beams are being utilized for the measurements of the resonance-averaged nuclear parameters. In the first experiments aiming partly at testing the adequacy of the experimental conditions total neutron cross-sections have been measured by transmission technique for U-238 and C-12 target nuclei. The data for U-238 obtained with the accuracy of about 1% were compared with the evaluated ENDF/B-IV data and the results of recent experimental works. (author). 4 figs, 6 refs, 2 tabs.}
place = {Viet Nam}
year = {1993}
month = {Apr}
}