Abstract
In the piercing horizontal channel of the Dalat nuclear research reactor a 98cm long silicon filter has been installed for producing quasi-monoenergetic neutrons of 55 keV and 144 keV. The flux intensities of the neutron beams are 4x10{sup 6} n/cm{sup 2}.s (55 keV) and 1.2x10{sup 7} n/cm{sup 2}.s (144 keV). Filtered neutron beams are being utilized for the measurements of the resonance-averaged nuclear parameters. In the first experiments aiming partly at testing the adequacy of the experimental conditions total neutron cross-sections have been measured by transmission technique for U-238 and C-12 target nuclei. The data for U-238 obtained with the accuracy of about 1% were compared with the evaluated ENDF/B-IV data and the results of recent experimental works. (author). 4 figs, 6 refs, 2 tabs.
Citation Formats
Hien, Pham Zuy, Tan, Vuong Huu, and Xuan, Nguyen Phuoc.
Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV.
Viet Nam: N. p.,
1993.
Web.
Hien, Pham Zuy, Tan, Vuong Huu, & Xuan, Nguyen Phuoc.
Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV.
Viet Nam.
Hien, Pham Zuy, Tan, Vuong Huu, and Xuan, Nguyen Phuoc.
1993.
"Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV."
Viet Nam.
@misc{etde_10135372,
title = {Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV}
author = {Hien, Pham Zuy, Tan, Vuong Huu, and Xuan, Nguyen Phuoc}
abstractNote = {In the piercing horizontal channel of the Dalat nuclear research reactor a 98cm long silicon filter has been installed for producing quasi-monoenergetic neutrons of 55 keV and 144 keV. The flux intensities of the neutron beams are 4x10{sup 6} n/cm{sup 2}.s (55 keV) and 1.2x10{sup 7} n/cm{sup 2}.s (144 keV). Filtered neutron beams are being utilized for the measurements of the resonance-averaged nuclear parameters. In the first experiments aiming partly at testing the adequacy of the experimental conditions total neutron cross-sections have been measured by transmission technique for U-238 and C-12 target nuclei. The data for U-238 obtained with the accuracy of about 1% were compared with the evaluated ENDF/B-IV data and the results of recent experimental works. (author). 4 figs, 6 refs, 2 tabs.}
place = {Viet Nam}
year = {1993}
month = {Apr}
}
title = {Total neutron cross-section of U-238 as measured with filtered neutrons of 55 keV and 144 keV}
author = {Hien, Pham Zuy, Tan, Vuong Huu, and Xuan, Nguyen Phuoc}
abstractNote = {In the piercing horizontal channel of the Dalat nuclear research reactor a 98cm long silicon filter has been installed for producing quasi-monoenergetic neutrons of 55 keV and 144 keV. The flux intensities of the neutron beams are 4x10{sup 6} n/cm{sup 2}.s (55 keV) and 1.2x10{sup 7} n/cm{sup 2}.s (144 keV). Filtered neutron beams are being utilized for the measurements of the resonance-averaged nuclear parameters. In the first experiments aiming partly at testing the adequacy of the experimental conditions total neutron cross-sections have been measured by transmission technique for U-238 and C-12 target nuclei. The data for U-238 obtained with the accuracy of about 1% were compared with the evaluated ENDF/B-IV data and the results of recent experimental works. (author). 4 figs, 6 refs, 2 tabs.}
place = {Viet Nam}
year = {1993}
month = {Apr}
}