The conception of a humid air cooling tower with natural or forced draught, requires the knowledge of the thermal and aerodynamic exchange surfaces performances. Several points, among which the distribution nozzles and drift eliminators efficiencies, or the mechanical behavior of the components, should be considered. In order to be able to test this type of equipment and analyse its behavior, ELECTRICITE DE FRANCE set up in 1987 of a large dimensions test bench: MISTRAL. The investigations performed over the 3000 working hours of MISTRAL concern mainly the optimization of the counterflow and crossflow exchange surfaces proposed by the industrial cooling tower equipment suppliers. The quality of the experimental results is assured by the implementation of an extensive instrumentation on the air and water circuits, and by a severe control of the tests conditions.
Citation Formats
Legrand, G.
Studies of cooling tower components on the Mistral test bench; Etudes de composants d`aerorefrigerants sur le banc d`essais Mistral.
France: N. p.,
1992.
Web.
Legrand, G.
Studies of cooling tower components on the Mistral test bench; Etudes de composants d`aerorefrigerants sur le banc d`essais Mistral.
France.
Legrand, G.
1992.
"Studies of cooling tower components on the Mistral test bench; Etudes de composants d`aerorefrigerants sur le banc d`essais Mistral."
France.
@misc{etde_10132142,
title = {Studies of cooling tower components on the Mistral test bench; Etudes de composants d`aerorefrigerants sur le banc d`essais Mistral}
author = {Legrand, G}
abstractNote = {The conception of a humid air cooling tower with natural or forced draught, requires the knowledge of the thermal and aerodynamic exchange surfaces performances. Several points, among which the distribution nozzles and drift eliminators efficiencies, or the mechanical behavior of the components, should be considered. In order to be able to test this type of equipment and analyse its behavior, ELECTRICITE DE FRANCE set up in 1987 of a large dimensions test bench: MISTRAL. The investigations performed over the 3000 working hours of MISTRAL concern mainly the optimization of the counterflow and crossflow exchange surfaces proposed by the industrial cooling tower equipment suppliers. The quality of the experimental results is assured by the implementation of an extensive instrumentation on the air and water circuits, and by a severe control of the tests conditions.}
place = {France}
year = {1992}
month = {Jul}
}
title = {Studies of cooling tower components on the Mistral test bench; Etudes de composants d`aerorefrigerants sur le banc d`essais Mistral}
author = {Legrand, G}
abstractNote = {The conception of a humid air cooling tower with natural or forced draught, requires the knowledge of the thermal and aerodynamic exchange surfaces performances. Several points, among which the distribution nozzles and drift eliminators efficiencies, or the mechanical behavior of the components, should be considered. In order to be able to test this type of equipment and analyse its behavior, ELECTRICITE DE FRANCE set up in 1987 of a large dimensions test bench: MISTRAL. The investigations performed over the 3000 working hours of MISTRAL concern mainly the optimization of the counterflow and crossflow exchange surfaces proposed by the industrial cooling tower equipment suppliers. The quality of the experimental results is assured by the implementation of an extensive instrumentation on the air and water circuits, and by a severe control of the tests conditions.}
place = {France}
year = {1992}
month = {Jul}
}