Abstract
The present paper reports the results of an investigation carried out by one ofthe laboratories of ENEA (Italian National Agency for New Technologies, Energy and Environment) about the thermal features of the ovens used for annealing treatments of TL dosimeters. A total number of 45 commercial ovens and muffle furnaces were studied, belonging to 24 Italian health physics laboratories. The investigation has shown that the majority of the ovens do not possess a degree of accuracy, stability, uniformity and reproducibility suitable for their use in the field of thermoluminescence dosimetry. Practical suggestions are also given in order to reduce the effects of some of the negative characteristics found in most ovens.
Citation Formats
Scarpa, G, Caporali, C, and Moscati, M.
Survey on thermal features of ovens used for annealing treatments of TL dosimeters; Indagine sulle specifiche dei forni usati per i trattamenti termici dei rilevatori a termoluminescenza.
Italy: N. p.,
1991.
Web.
Scarpa, G, Caporali, C, & Moscati, M.
Survey on thermal features of ovens used for annealing treatments of TL dosimeters; Indagine sulle specifiche dei forni usati per i trattamenti termici dei rilevatori a termoluminescenza.
Italy.
Scarpa, G, Caporali, C, and Moscati, M.
1991.
"Survey on thermal features of ovens used for annealing treatments of TL dosimeters; Indagine sulle specifiche dei forni usati per i trattamenti termici dei rilevatori a termoluminescenza."
Italy.
@misc{etde_10131759,
title = {Survey on thermal features of ovens used for annealing treatments of TL dosimeters; Indagine sulle specifiche dei forni usati per i trattamenti termici dei rilevatori a termoluminescenza}
author = {Scarpa, G, Caporali, C, and Moscati, M}
abstractNote = {The present paper reports the results of an investigation carried out by one ofthe laboratories of ENEA (Italian National Agency for New Technologies, Energy and Environment) about the thermal features of the ovens used for annealing treatments of TL dosimeters. A total number of 45 commercial ovens and muffle furnaces were studied, belonging to 24 Italian health physics laboratories. The investigation has shown that the majority of the ovens do not possess a degree of accuracy, stability, uniformity and reproducibility suitable for their use in the field of thermoluminescence dosimetry. Practical suggestions are also given in order to reduce the effects of some of the negative characteristics found in most ovens.}
place = {Italy}
year = {1991}
month = {Apr}
}
title = {Survey on thermal features of ovens used for annealing treatments of TL dosimeters; Indagine sulle specifiche dei forni usati per i trattamenti termici dei rilevatori a termoluminescenza}
author = {Scarpa, G, Caporali, C, and Moscati, M}
abstractNote = {The present paper reports the results of an investigation carried out by one ofthe laboratories of ENEA (Italian National Agency for New Technologies, Energy and Environment) about the thermal features of the ovens used for annealing treatments of TL dosimeters. A total number of 45 commercial ovens and muffle furnaces were studied, belonging to 24 Italian health physics laboratories. The investigation has shown that the majority of the ovens do not possess a degree of accuracy, stability, uniformity and reproducibility suitable for their use in the field of thermoluminescence dosimetry. Practical suggestions are also given in order to reduce the effects of some of the negative characteristics found in most ovens.}
place = {Italy}
year = {1991}
month = {Apr}
}