You need JavaScript to view this

Preliminary study of tomographic system for controlling quality of cemented low and medium activity wastes; Ipotesi di fattibilita` di un tomografo per il controllo di qualita` di matrici cementizie inglobanti residui radioattivi a media e bassa attivita`

Abstract

A preliminary study of a tomographic system for controlling the quality of the cemented low and intermediate radioactive wastes has been carried out by Italian ENEA and University of Rome `La Sapienza`. A comparative evaluation of `Single Pencil Beam` and `Fan Beam` configurations has been performed. `Single Pencil Beam` tomography - for analyzed cement samples - requests too long total counting time (one day), for 10 percent precision on reconstructed absorption coefficient value.`Fan Beam` results more practicable solution: in the same counting time it allows one percent precision.
Publication Date:
Mar 01, 1991
Product Type:
Technical Report
Report Number:
ENEA-RT-NUCL-90-17; RT/NUCL-90-17
Reference Number:
SCA: 440101; 052001; 070204; 360206; PA: ITAN-92:001068; SN: 92000694193
Resource Relation:
Other Information: PBD: Mar 1991
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; 12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; 07 ISOTOPES AND RADIATION SOURCES; 36 MATERIALS SCIENCE; LOW-LEVEL RADIOACTIVE WASTES; COMPUTERIZED TOMOGRAPHY; INTERMEDIATE-LEVEL RADIOACTIVE WASTES; COMPARATIVE EVALUATIONS; ITALIAN ENEA; RADIATION ABSORPTION ANALYSIS; NUCLEAR MATERIALS MANAGEMENT; CEMENTS; EXPERIMENTAL DATA; MATERIALS TESTING; 440101; 052001; 070204; 360206; GENERAL DETECTORS OR MONITORS AND RADIOMETRIC INSTRUMENTS; WASTE PROCESSING; INDUSTRIAL USES, RADIOMETRIC; RADIATION EFFECTS
OSTI ID:
10131754
Research Organizations:
Rome Univ. (Italy). Dipt. di Energetica; ENEA, Casaccia (Italy). Area Nucleare
Country of Origin:
Italy
Language:
Italian
Other Identifying Numbers:
Journal ID: ISSN 1120-5598; Other: ON: DE92789513; TRN: 92:001068
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
ITAN
Size:
18 p.
Announcement Date:
Jul 04, 2005

Citation Formats

Cenci, S, Remetti, R, Dionisi, M, and Zeppa, P. Preliminary study of tomographic system for controlling quality of cemented low and medium activity wastes; Ipotesi di fattibilita` di un tomografo per il controllo di qualita` di matrici cementizie inglobanti residui radioattivi a media e bassa attivita`. Italy: N. p., 1991. Web.
Cenci, S, Remetti, R, Dionisi, M, & Zeppa, P. Preliminary study of tomographic system for controlling quality of cemented low and medium activity wastes; Ipotesi di fattibilita` di un tomografo per il controllo di qualita` di matrici cementizie inglobanti residui radioattivi a media e bassa attivita`. Italy.
Cenci, S, Remetti, R, Dionisi, M, and Zeppa, P. 1991. "Preliminary study of tomographic system for controlling quality of cemented low and medium activity wastes; Ipotesi di fattibilita` di un tomografo per il controllo di qualita` di matrici cementizie inglobanti residui radioattivi a media e bassa attivita`." Italy.
@misc{etde_10131754,
title = {Preliminary study of tomographic system for controlling quality of cemented low and medium activity wastes; Ipotesi di fattibilita` di un tomografo per il controllo di qualita` di matrici cementizie inglobanti residui radioattivi a media e bassa attivita`}
author = {Cenci, S, Remetti, R, Dionisi, M, and Zeppa, P}
abstractNote = {A preliminary study of a tomographic system for controlling the quality of the cemented low and intermediate radioactive wastes has been carried out by Italian ENEA and University of Rome `La Sapienza`. A comparative evaluation of `Single Pencil Beam` and `Fan Beam` configurations has been performed. `Single Pencil Beam` tomography - for analyzed cement samples - requests too long total counting time (one day), for 10 percent precision on reconstructed absorption coefficient value.`Fan Beam` results more practicable solution: in the same counting time it allows one percent precision.}
place = {Italy}
year = {1991}
month = {Mar}
}