You need JavaScript to view this

Emittance measurement at HyperECR

Abstract

An emittance scanner has been installed in the beam line of the HyperECR ion source. It takes about 4 min to measure the emittance for the horizontal and vertical directions. Typical 90 % emittance was measured to be about 160 {pi}mm{center_dot}mrad in the horizontal direction and 200 {pi}mm{center_dot}mrad in the vertical direction in the case of 100 e{mu}A of Ar{sup 8+} at 20 kV extraction voltage. Dependence of the emittance on the extraction voltage, the charge state of the ions, the beam current and the diameter of the extraction hole was measured. (author).
Authors:
Yamashita, Y; Isoya, Y; [1]  Sekiguchi, M
  1. Japan Steel Works Ltd., Tokyo (Japan)
Publication Date:
Jul 01, 1993
Product Type:
Technical Report
Report Number:
INS-994
Reference Number:
SCA: 430301; PA: JPN-94:001016; EDB-94:046836; ERA-19:012855; NTS-94:017843; SN: 94001163718
Resource Relation:
Other Information: PBD: Jul 1993
Subject:
43 PARTICLE ACCELERATORS; ION SOURCES; BEAM EMITTANCE; ELECTRON CYCLOTRON-RESONANCE; CHARGE STATES; BEAM CURRENTS; BEAM EXTRACTION; ELECTRODES; PERFORMANCE TESTING; ARGON IONS; 430301
OSTI ID:
10131541
Research Organizations:
Tokyo Univ., Tanashi (Japan). Inst. for Nuclear Study
Country of Origin:
Japan
Language:
English
Other Identifying Numbers:
Other: ON: DE94748501; TRN: JP9401016
Availability:
OSTI; NTIS; INIS
Submitting Site:
JPN
Size:
4 p.
Announcement Date:
Jul 04, 2005

Citation Formats

Yamashita, Y, Isoya, Y, and Sekiguchi, M. Emittance measurement at HyperECR. Japan: N. p., 1993. Web.
Yamashita, Y, Isoya, Y, & Sekiguchi, M. Emittance measurement at HyperECR. Japan.
Yamashita, Y, Isoya, Y, and Sekiguchi, M. 1993. "Emittance measurement at HyperECR." Japan.
@misc{etde_10131541,
title = {Emittance measurement at HyperECR}
author = {Yamashita, Y, Isoya, Y, and Sekiguchi, M}
abstractNote = {An emittance scanner has been installed in the beam line of the HyperECR ion source. It takes about 4 min to measure the emittance for the horizontal and vertical directions. Typical 90 % emittance was measured to be about 160 {pi}mm{center_dot}mrad in the horizontal direction and 200 {pi}mm{center_dot}mrad in the vertical direction in the case of 100 e{mu}A of Ar{sup 8+} at 20 kV extraction voltage. Dependence of the emittance on the extraction voltage, the charge state of the ions, the beam current and the diameter of the extraction hole was measured. (author).}
place = {Japan}
year = {1993}
month = {Jul}
}