Abstract

This report deals with the analysis and qualification of some representative feeders of 500 MWe PHWR. There are 196 different feeder pipe configurations for a total of 748 feeders. Analysing these many configurations is a difficult task. Therefore, the present analysis was aimed at evolving a generalised supporting criteria based on the analysis of some representative feeders. For this purpose, these feeder pipes were classified into 4 groups based on their geometrical configurations. A total of 7 feeders were selected, which broadly represent the feeders of all the 4 groups. Many of these feeders are interconnected by spacers, which make their analysis for earthquake loadings quite complex. The analysis was carried out for various loadings viz., temperature, pressure, dead weight and operating basis earthquake (OBE). The analysis for OBE loading was carried out using response spectrum Method. Based on the analysis of 7 feeders, generic supporting arrangements for feeders of various group have been suggested. The report gives in detail the input data used, mathematical modelling, analysis approach, various supporting criteria evolved, the optimised supporting criteria and the conclusions arrived at. (author). 20 refs., 18 figs., 28 tabs., 1 appendix.
Authors:
Soni, R S; Kushwaha, H S; Mahajan, S C; Kakodkar, A; [1]  Prasad, K H; Gupta, K N; Bapat, C N; Sharma, V K [2] 
  1. Bhabha Atomic Research Centre, Bombay (India). Reactor Engineering Div.
  2. Nuclear Power Corp., Bombay (India)
Publication Date:
Dec 31, 1993
Product Type:
Technical Report
Report Number:
BARC-1993/E/012
Reference Number:
SCA: 210400; PA: AIX-25:018845; EDB-94:035702; ERA-19:012147; NTS-94:015281; SN: 94001159827
Resource Relation:
Other Information: PBD: 1993
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; PHWR TYPE REACTORS; PIPES; REACTOR COOLING SYSTEMS; BOUNDARY CONDITIONS; CREEP; DAMPING; DESIGN; DYNAMIC LOADS; EARTHQUAKES; FINITE ELEMENT METHOD; MATHEMATICAL MODELS; MECHANICAL VIBRATIONS; NOZZLES; REACTOR COMPONENTS; RESPONSE FUNCTIONS; SPACERS; SPECIFICATIONS; SPECTRA; STRESSES; SUPPORTS; 210400; POWER REACTORS, NONBREEDING, OTHERWISE MODERATED OR UNMODERATED
OSTI ID:
10130587
Research Organizations:
Bhabha Atomic Research Centre, Bombay (India)
Country of Origin:
India
Language:
English
Other Identifying Numbers:
Other: ON: DE94616341; TRN: IN9400053018845
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
148 p.
Announcement Date:
Jul 04, 2005

Citation Formats

Soni, R S, Kushwaha, H S, Mahajan, S C, Kakodkar, A, Prasad, K H, Gupta, K N, Bapat, C N, and Sharma, V K. Evolution of supporting conditions for some representative feeders of 500 MWe PHWR. India: N. p., 1993. Web.
Soni, R S, Kushwaha, H S, Mahajan, S C, Kakodkar, A, Prasad, K H, Gupta, K N, Bapat, C N, & Sharma, V K. Evolution of supporting conditions for some representative feeders of 500 MWe PHWR. India.
Soni, R S, Kushwaha, H S, Mahajan, S C, Kakodkar, A, Prasad, K H, Gupta, K N, Bapat, C N, and Sharma, V K. 1993. "Evolution of supporting conditions for some representative feeders of 500 MWe PHWR." India.
@misc{etde_10130587,
title = {Evolution of supporting conditions for some representative feeders of 500 MWe PHWR}
author = {Soni, R S, Kushwaha, H S, Mahajan, S C, Kakodkar, A, Prasad, K H, Gupta, K N, Bapat, C N, and Sharma, V K}
abstractNote = {This report deals with the analysis and qualification of some representative feeders of 500 MWe PHWR. There are 196 different feeder pipe configurations for a total of 748 feeders. Analysing these many configurations is a difficult task. Therefore, the present analysis was aimed at evolving a generalised supporting criteria based on the analysis of some representative feeders. For this purpose, these feeder pipes were classified into 4 groups based on their geometrical configurations. A total of 7 feeders were selected, which broadly represent the feeders of all the 4 groups. Many of these feeders are interconnected by spacers, which make their analysis for earthquake loadings quite complex. The analysis was carried out for various loadings viz., temperature, pressure, dead weight and operating basis earthquake (OBE). The analysis for OBE loading was carried out using response spectrum Method. Based on the analysis of 7 feeders, generic supporting arrangements for feeders of various group have been suggested. The report gives in detail the input data used, mathematical modelling, analysis approach, various supporting criteria evolved, the optimised supporting criteria and the conclusions arrived at. (author). 20 refs., 18 figs., 28 tabs., 1 appendix.}
place = {India}
year = {1993}
month = {Dec}
}