The dynamic daphnia test: First experiences in immission and emission control of waters and discharges in Hesse; Der dynamische Daphnientest: Erste Erfahrungen in der Immissions- und Emissionsueberwachung an Gewaessern und Einleitungen in Hessen

Abstract

The ascertainment of the state of waters or their toxicity by means of biological systems, is a useful practice of immission and emitter control lasting for years. With automized biotest systems, which can control waters or waste water discharges around the clock, new efficient possibilities are opened for water protection. With this, a substitute of chemical control methods by biological tests in not thought for. On the contrary, the alarm caused by the automatic daphay test is to facilitate the purposive application of expensive chemical methods. This export presents the results from the laboratory and first experiences from two positions. (orig./BBR). [Deutsch] Mit biologischen Systemen den Zustand eines Gewaessers oder die Giftigkeit eines Abwassers festzustellen, ist bereits jahrelang geuebte Praxis der Immissions- und Emittentenkontrolle. Mit automatisierten Biotestsystemen, die vor Ort rund um die Uhr ein Gewaesser oder eine Abwassereinleitung ueberwachen koennen, eroeffnen sich neue, wirkungsvolle Moeglichkeiten fuer den Gewaesserschutz. Dabei ist nicht an einen Ersatz der chemischen Kontrollmethoden durch biologische Tests gedacht. Vielmehr soll der durch den automatischen Daphnientest ausgeloeste Alarm den gezielten Einsatz der kostspieligen chemischen Verfahren moeglich machen. Der vorliegende Bericht stellt die Ergebnisse aus dem Labor und erste Erfahrungen von zwei Standorten dar. (orig./BBR).
Authors:
Publication Date:
Oct 15, 1990
Product Type:
Miscellaneous
Report Number:
ETDE-mf-92784538
Reference Number:
SCA: 540320; PA: DE-92:002618; SN: 92000687466
Resource Relation:
Journal Issue: no. 112; Other Information: PBD: 15 Oct 1990; Related Information: Umweltplanung, Arbeits- und Umweltschutz
Subject:
54 ENVIRONMENTAL SCIENCES; WATER POLLUTION MONITORS; BIOLOGICAL INDICATORS; AUTOMATION; DAPHNIA; WATER POLLUTION; RIVERS; WASTE WATER; TOXICITY; ALARM SYSTEMS; 540320; CHEMICALS MONITORING AND TRANSPORT
OSTI ID:
10130558
Research Organizations:
Hessische Landesanstalt fuer Umwelt, Wiesbaden (Germany)
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE92784538; ISBN 3-89026-111-6; TRN: DE9202618
Availability:
OSTI; NTIS (US Sales Only)
Submitting Site:
DE
Size:
33 p.
Announcement Date:
Jul 04, 2005

Citation Formats

Deventer, K. The dynamic daphnia test: First experiences in immission and emission control of waters and discharges in Hesse; Der dynamische Daphnientest: Erste Erfahrungen in der Immissions- und Emissionsueberwachung an Gewaessern und Einleitungen in Hessen. Germany: N. p., 1990. Web.
Deventer, K. The dynamic daphnia test: First experiences in immission and emission control of waters and discharges in Hesse; Der dynamische Daphnientest: Erste Erfahrungen in der Immissions- und Emissionsueberwachung an Gewaessern und Einleitungen in Hessen. Germany.
Deventer, K. 1990. "The dynamic daphnia test: First experiences in immission and emission control of waters and discharges in Hesse; Der dynamische Daphnientest: Erste Erfahrungen in der Immissions- und Emissionsueberwachung an Gewaessern und Einleitungen in Hessen." Germany.
@misc{etde_10130558,
title = {The dynamic daphnia test: First experiences in immission and emission control of waters and discharges in Hesse; Der dynamische Daphnientest: Erste Erfahrungen in der Immissions- und Emissionsueberwachung an Gewaessern und Einleitungen in Hessen}
author = {Deventer, K}
abstractNote = {The ascertainment of the state of waters or their toxicity by means of biological systems, is a useful practice of immission and emitter control lasting for years. With automized biotest systems, which can control waters or waste water discharges around the clock, new efficient possibilities are opened for water protection. With this, a substitute of chemical control methods by biological tests in not thought for. On the contrary, the alarm caused by the automatic daphay test is to facilitate the purposive application of expensive chemical methods. This export presents the results from the laboratory and first experiences from two positions. (orig./BBR). [Deutsch] Mit biologischen Systemen den Zustand eines Gewaessers oder die Giftigkeit eines Abwassers festzustellen, ist bereits jahrelang geuebte Praxis der Immissions- und Emittentenkontrolle. Mit automatisierten Biotestsystemen, die vor Ort rund um die Uhr ein Gewaesser oder eine Abwassereinleitung ueberwachen koennen, eroeffnen sich neue, wirkungsvolle Moeglichkeiten fuer den Gewaesserschutz. Dabei ist nicht an einen Ersatz der chemischen Kontrollmethoden durch biologische Tests gedacht. Vielmehr soll der durch den automatischen Daphnientest ausgeloeste Alarm den gezielten Einsatz der kostspieligen chemischen Verfahren moeglich machen. Der vorliegende Bericht stellt die Ergebnisse aus dem Labor und erste Erfahrungen von zwei Standorten dar. (orig./BBR).}
issue = {no. 112}
place = {Germany}
year = {1990}
month = {Oct}
}