Abstract
The spacing characteristics of modular hadron sampling-calorimeter with cell sizes 75x75 mm{sup 2} are presented. Measurements for 36 modules were performed using {pi}{sup -} meson beam with the energy of 40 GeV. The dependence of the space resolution of the calorimeter on the impact point of the incident particles, cell sizes and beam energy have been studied. 12 refs.; 4 figs.
Gavrishchuk, O P;
Eremeev, R V;
Kadykov, M G;
Kosarev, I G;
Shalygin, A B;
Yukaev, A N;
[1]
Semenov, V K
[2]
- Joint Inst. for Nuclear Research, Dubna (Russian Federation). Lab. of High Energy
- Gosudarstvennyj Komitet po Ispol`zovaniyu Atomnoj Ehnergii SSSR (Russian Federation)
Citation Formats
Gavrishchuk, O P, Eremeev, R V, Kadykov, M G, Kosarev, I G, Shalygin, A B, Yukaev, A N, and Semenov, V K.
Spacing resolution of the central part of the hadron sampling-calorimeter HC-600; Koordinatnoe razreshenie tsentral`noj chasti adronnogo sehmpling-kalorimetra AK-600.
JINR: N. p.,
1991.
Web.
Gavrishchuk, O P, Eremeev, R V, Kadykov, M G, Kosarev, I G, Shalygin, A B, Yukaev, A N, & Semenov, V K.
Spacing resolution of the central part of the hadron sampling-calorimeter HC-600; Koordinatnoe razreshenie tsentral`noj chasti adronnogo sehmpling-kalorimetra AK-600.
JINR.
Gavrishchuk, O P, Eremeev, R V, Kadykov, M G, Kosarev, I G, Shalygin, A B, Yukaev, A N, and Semenov, V K.
1991.
"Spacing resolution of the central part of the hadron sampling-calorimeter HC-600; Koordinatnoe razreshenie tsentral`noj chasti adronnogo sehmpling-kalorimetra AK-600."
JINR.
@misc{etde_10128420,
title = {Spacing resolution of the central part of the hadron sampling-calorimeter HC-600; Koordinatnoe razreshenie tsentral`noj chasti adronnogo sehmpling-kalorimetra AK-600}
author = {Gavrishchuk, O P, Eremeev, R V, Kadykov, M G, Kosarev, I G, Shalygin, A B, Yukaev, A N, and Semenov, V K}
abstractNote = {The spacing characteristics of modular hadron sampling-calorimeter with cell sizes 75x75 mm{sup 2} are presented. Measurements for 36 modules were performed using {pi}{sup -} meson beam with the energy of 40 GeV. The dependence of the space resolution of the calorimeter on the impact point of the incident particles, cell sizes and beam energy have been studied. 12 refs.; 4 figs.}
place = {JINR}
year = {1991}
month = {Dec}
}
title = {Spacing resolution of the central part of the hadron sampling-calorimeter HC-600; Koordinatnoe razreshenie tsentral`noj chasti adronnogo sehmpling-kalorimetra AK-600}
author = {Gavrishchuk, O P, Eremeev, R V, Kadykov, M G, Kosarev, I G, Shalygin, A B, Yukaev, A N, and Semenov, V K}
abstractNote = {The spacing characteristics of modular hadron sampling-calorimeter with cell sizes 75x75 mm{sup 2} are presented. Measurements for 36 modules were performed using {pi}{sup -} meson beam with the energy of 40 GeV. The dependence of the space resolution of the calorimeter on the impact point of the incident particles, cell sizes and beam energy have been studied. 12 refs.; 4 figs.}
place = {JINR}
year = {1991}
month = {Dec}
}