You need JavaScript to view this

The ZEUS calorimeter first level trigger

Abstract

The design of the ZEUS Calorimeter First Level Trigger (CFLT) is presented. The CFLT utilizes a pipelined architecture to provide trigger data for a global first leel trigger decision 5 {mu}sec after each beam crossing, occurring every 96 nsec. The charges from 13K phototubes are summed into 1792 trigger tower pulseheights which are digitized by flash ADC`s. The digital values are linearized, stored and used for sums and pattern tests. Summary data is forwarded to the Global First Level Trigger for each crossing 2 {mu}sec after the crossing occurred. The CFLT determines the total energy, the total transverse energy, the missing energy, and the energy and number of isolated electrons and muons. It also provides information on the electromagnetic and hadronic energy deposited in various regions of the calorimeter. The CFLT has kept the experimental trigger rate below {approx}200 Hz at the highest luminosity experienced at HERA. Performance studies suggest that the CFLT will keep the trigger rate below 1 kHZ against a rate of proton-beam gas interactions on the order of the 100 kHz expected at design luminosity. (orig.)
Authors:
Smith, W H; [1]  Ali, I; [1]  Behrens, B; [1]  Fordham, C; [1]  Foudas, C; [1]  Goussiou, A; [1]  Jaworski, M; [1]  Kinnel, T; [1]  Lackey, J; [1]  Robl, P; [1]  Silverstein, S; [1]  Dawson, J W; [2]  Krakauer, D A; [2]  Talaga, R L; [2]  Schlereth, J L [2] 
  1. Wisconsin Univ., Madison, WI (United States)
  2. Argonne National Lab., Washington, DC (United States)
Publication Date:
Oct 01, 1994
Product Type:
Technical Report
Report Number:
DESY-94-183
Reference Number:
SCA: 440104; PA: DEN-95:0F5582; EDB-95:052877; SN: 95001361385
Resource Relation:
Other Information: PBD: Oct 1994
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; CALORIMETERS; TRIGGER CIRCUITS; HERA STORAGE RING; LOGIC CIRCUITS; ANALOG-TO-DIGITAL CONVERTERS; COLLIDING BEAMS; ELECTRON BEAMS; TRANSVERSE ENERGY; PROTON BEAMS; PHOTOMULTIPLIERS; ELECTRON SPECTROSCOPY; ELECTRON DETECTION; MUON DETECTION; ENERGY DEPOSITION; PARTICLE IDENTIFICATION; CALIBRATION; ALGORITHMS; EFFICIENCY; ENERGY DEPENDENCE; GEV RANGE 01-10; GEV RANGE 10-100; RELATIVISTIC RANGE; 440104; HIGH ENERGY PHYSICS INSTRUMENTATION
OSTI ID:
10128392
Research Organizations:
Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)
Country of Origin:
Germany
Language:
English
Other Identifying Numbers:
Journal ID: ISSN 0418-9833; Other: ON: DE95756054; TRN: DE95F5582
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
DEN
Size:
37 p.
Announcement Date:
Jul 04, 2005

Citation Formats

Smith, W H, Ali, I, Behrens, B, Fordham, C, Foudas, C, Goussiou, A, Jaworski, M, Kinnel, T, Lackey, J, Robl, P, Silverstein, S, Dawson, J W, Krakauer, D A, Talaga, R L, and Schlereth, J L. The ZEUS calorimeter first level trigger. Germany: N. p., 1994. Web.
Smith, W H, Ali, I, Behrens, B, Fordham, C, Foudas, C, Goussiou, A, Jaworski, M, Kinnel, T, Lackey, J, Robl, P, Silverstein, S, Dawson, J W, Krakauer, D A, Talaga, R L, & Schlereth, J L. The ZEUS calorimeter first level trigger. Germany.
Smith, W H, Ali, I, Behrens, B, Fordham, C, Foudas, C, Goussiou, A, Jaworski, M, Kinnel, T, Lackey, J, Robl, P, Silverstein, S, Dawson, J W, Krakauer, D A, Talaga, R L, and Schlereth, J L. 1994. "The ZEUS calorimeter first level trigger." Germany.
@misc{etde_10128392,
title = {The ZEUS calorimeter first level trigger}
author = {Smith, W H, Ali, I, Behrens, B, Fordham, C, Foudas, C, Goussiou, A, Jaworski, M, Kinnel, T, Lackey, J, Robl, P, Silverstein, S, Dawson, J W, Krakauer, D A, Talaga, R L, and Schlereth, J L}
abstractNote = {The design of the ZEUS Calorimeter First Level Trigger (CFLT) is presented. The CFLT utilizes a pipelined architecture to provide trigger data for a global first leel trigger decision 5 {mu}sec after each beam crossing, occurring every 96 nsec. The charges from 13K phototubes are summed into 1792 trigger tower pulseheights which are digitized by flash ADC`s. The digital values are linearized, stored and used for sums and pattern tests. Summary data is forwarded to the Global First Level Trigger for each crossing 2 {mu}sec after the crossing occurred. The CFLT determines the total energy, the total transverse energy, the missing energy, and the energy and number of isolated electrons and muons. It also provides information on the electromagnetic and hadronic energy deposited in various regions of the calorimeter. The CFLT has kept the experimental trigger rate below {approx}200 Hz at the highest luminosity experienced at HERA. Performance studies suggest that the CFLT will keep the trigger rate below 1 kHZ against a rate of proton-beam gas interactions on the order of the 100 kHz expected at design luminosity. (orig.)}
place = {Germany}
year = {1994}
month = {Oct}
}