You need JavaScript to view this

Tracking detector based on capillaries with liquid scintillator

Abstract

A tracking detector with bundles of capillaries 20-25 mum in diameter, 0.4 m long filled with a new liquid scintillator exposed to the 70 GeV/c p{sup +} beam has been studied. An attenuation length of 60-80 cm at distances L>20 cm is obtained. Hit density on a track at a distance L=155 mm is n=4.4 mm{sup -1} and n{sub 0}=9.6 mm{sup -1} at L=0. A straight-line RMS residual is {sigma}{sub tr}=30 mum, the two track resolution is {sigma}{sub tt}=57 mum. The light detected outside the track region ({+-}3{sigma}{sub tt}) is 14% of the total detected light. 4 refs.; 7 figs.; 1 tab.
Authors:
Bozhko, N I; Golovkin, S V; Gorin, A M [1] 
  1. and others
Publication Date:
Dec 31, 1991
Product Type:
Technical Report
Report Number:
IHEP-OEF-91-45; IFVE-OEF-91-45.
Reference Number:
SCA: 440104; PA: AIX-23:026323; SN: 92000685980
Resource Relation:
Other Information: PBD: 1991
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; LIQUID SCINTILLATION DETECTORS; PARTICLE TRACKS; GEV RANGE 01-10; PERFORMANCE TESTING; PROTON BEAMS; SPATIAL RESOLUTION; 440104; HIGH ENERGY PHYSICS INSTRUMENTATION
OSTI ID:
10128366
Research Organizations:
Gosudarstvennyj Komitet po Ispol`zovaniyu Atomnoj Ehnergii SSSR, Serpukhov (Russian Federation). Inst. Fiziki Vysokikh Ehnergij
Country of Origin:
USSR
Language:
English
Other Identifying Numbers:
Other: ON: DE92620921; TRN: SU9200946026323
Availability:
OSTI; NTIS (US Sales Only); INIS
Submitting Site:
INIS
Size:
10 p.
Announcement Date:
Jul 04, 2005

Citation Formats

Bozhko, N I, Golovkin, S V, and Gorin, A M. Tracking detector based on capillaries with liquid scintillator. USSR: N. p., 1991. Web.
Bozhko, N I, Golovkin, S V, & Gorin, A M. Tracking detector based on capillaries with liquid scintillator. USSR.
Bozhko, N I, Golovkin, S V, and Gorin, A M. 1991. "Tracking detector based on capillaries with liquid scintillator." USSR.
@misc{etde_10128366,
title = {Tracking detector based on capillaries with liquid scintillator}
author = {Bozhko, N I, Golovkin, S V, and Gorin, A M}
abstractNote = {A tracking detector with bundles of capillaries 20-25 mum in diameter, 0.4 m long filled with a new liquid scintillator exposed to the 70 GeV/c p{sup +} beam has been studied. An attenuation length of 60-80 cm at distances L>20 cm is obtained. Hit density on a track at a distance L=155 mm is n=4.4 mm{sup -1} and n{sub 0}=9.6 mm{sup -1} at L=0. A straight-line RMS residual is {sigma}{sub tr}=30 mum, the two track resolution is {sigma}{sub tt}=57 mum. The light detected outside the track region ({+-}3{sigma}{sub tt}) is 14% of the total detected light. 4 refs.; 7 figs.; 1 tab.}
place = {USSR}
year = {1991}
month = {Dec}
}